Power PCB Relay G6B 169
Non-latching, Double Pole
Single Coil Latching
Dual Coil Latching
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
2. Operating characteristics are measured at a coil temperature of 23°C.
■Characteristics
Note: The data shown above are initial values.
Rated
voltage
(VDC)
Rated
current
(mA)
Coil
resistance
(Ω)
Pick-up voltage Dropout voltage Max. voltage Power
consumption
(mW)
% of rated voltage
5 60 83.30 80% max. 10% min. 140% max.@ 23°C Approx. 300
6 50 120
12 25 480
24 12.50 1,920
Rated
voltage
(VDC)
Rated
current
(mA)
Coil
resistance
(Ω)
Coil inductance
(ref. value) (H)
Set pick-up
voltage
Reset pick-up
voltage
Maximum
voltage Power
consumption
(mW)
Armature OFF Armature ON % of rated voltage
5 40 125 0.28 0.26 70% max. 70% max. 160% max.
at 23°C
Approx. 200
6 33.30 180 0.31 0.28
12 16.70 720 1.2 1.10
24 8.30 2,880 4.9 4.10
Rated
voltage
(VDC)
Rated
current
(mA)
Coil
resistance
(Ω)
Coil inductance
(ref. value) (H)
Set
pick-up
voltage
Reset
pick-up
voltage
Maximum
voltage Power
consumption
(mW)
Armature OFF Armature ON % of rated voltage
5 56 89.20 0.15 0.15 70% max. 70% max. 130% max.
at 23°C
Approx. 280
6 46.80 128.50 0.18 0.18
12 23.30 515 0.52 0.52
24 11.70 2,060 1.20 1.20
Contact resistance 30 mΩ max.
Operate (set) time 10 ms max. (mean value: 1-pole approx. 3 ms, 2-pole approx. 4 ms)
Release (reset) time Non-latching 10 ms max. (mean value: 1-pole approx. 1 ms, 2-pole approx. 2 ms)
Latching 10 ms max. (mean value: approx. 3 ms)
Min. set/reset signal width Latching type: 15 ms min. (at 23°C)
Max. operating
frequency
Mechanical 18,000 operations/hr
Electrical 1,800 operations/hr (under rated load)
Insulation resistance 1,000 MΩ min. (at 500 VDC, at 250 VDC between set coil and reset coil)
Dielectric strength 3,000 VAC (Latching types: 2,000 VAC), 50/60 Hz for 1 min between coil and contacts
1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity
250 VAC, 50/60 Hz for 1 min between set and reset coils
2,000 VAC, 50/60 Hz for 1 min between contacts of different polarity
Vibration resistance Mechanical durability 10 to 55 Hz, 1.5-mm double amplitude
Malfunction durability 10 to 55 Hz, 1.5-mm double amplitude
Shock resistance Mechanical durability 1,000 m/s2 (Approx 100G)
Malfunction durability Single-side stable: 100 m/s2 (Approx 10G); Latching: 300 m/s2 (Approx 30G)
Service Life Mechanical 50,000,000 operations min. (at 18,000 operations/hr)
Electrical 100,000 operation min. (at 1,800 operations/hr)
Ambient temperature Operating: −25°C to 70°C (with no icing)
Ambient humidity Operating: 5% to 85%
Weight Double-winding latching: Approx. 3.7 g
High-capacity: Approx. 4.6 g
Double pole: Approx. 4.5 g
Other: Approx. 3.5 g