Standard Proximity Sensor E2E CSM_E2E_DS_E_12_1 Your Search for Proximity Sensors Starts with the World-leading Performance and Quality of the E2E (Standards do not apply to all models.) * Standard Sensors for detecting ferrous metals. * Wide array of variations. Ideal for a variety of applications. * Models with different frequencies are also available to prevent mutual interference. * Superior environment resistance with standard cable made of oilresistant PVC and sensing surface made of material that resists cutting oil. * Useful to help prevent disconnection. Cable protector provided as a standard feature. For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Be sure to read Safety Precautions on page 25. Features 2-Wire Models Pre-wired Models with Oil-resistant Reinforced PUR Cables Added to the Lineup and Easy Differentiation with Orange Head Oilil Resistance Differentiation from standard models: Orange Head Oil Resistance (Insulation service life): twice or three times that of oil-resistant vinyl chloride able Flexibility Cable Cable Flexibility: approximately twice that of vinyl chloride cables Cable able Flexibility at Low Temperatures More Flexibility at -40C Lineup includes models with Smartclick pre-wired connectors for fast connection. XS5 Smartclick connectors used to enable checking connector mating Jacket: Polyester elastomer Clic Insert all the way. k 1/8 turn Insulation: Oil-resistant grade PUR (polyurethane) UL-recognized Models Available 1 E2E Lineup includes models with self-diagnostic output to provide notification of failures and unstable detection conditions, such as coil burnout. * Contributes to preventive maintenance to keep the line from stopping. Reduced wiring, fewer resources, and low power consumption contribute to environmentalism. * Wiring work and amount of copper wire used reduced to two thirds of that required for 3-wire models. * Current consumption drastically reduced to less than 10% (when a DC 2-wire model is compared with a DC 3-wire model). 3-Wire Models Wide range of ambient operating temperatures: -40C to 85C (M8 to M30 models) * Suitable for low-temperature and high-temperature applications, which are troublesome for photoelectric sensors. Lineup includes models with flexible cable (M8 to M30 models) * Reduced risk of disconnection in applications with moving parts. 2 E2E E2E Guide to Selection by Purpose Environment -40 to 85C AC 2-wire: M12 to M30, DC 3-wire: M8 to M30 Wide operating temperature range -25 to 70C Models not listed above. Resists the influence of surrounding metal Maintenance Reducing stocked models NPN/PNP output AC/DC Shielded Models DC 2-Wire Models E2E-X@D@ AC/DC 2-Wire Models E2E-X@T1 Smartclick Pre-wired Connector Models E2E-X@D@-M1TGJ-(U)/(US) Easy replacement Pre-wired Connector Models E2E-X@D1-M1(G)J-(T) Connector Models E2E-X@D@-M1(G) E2E-X@E@-M1 E2E-X@Y@-M1 Reducing troubles Higher oil resistance Reinforced Standard Mounting to moving parts Models with Oil-resistant PVC cable Robotics Cable Models E2E-X@D1-R E2E-X@E1-R Robotics cable Mutual interference prevention Miswiring measures Models with Oil-resistor reinforced PUR cable E2E-X@D@-U Models with a Different Frequency (NO Models only) E2E-X@@15 Load short-circuit protection DC 2-Wire Models E2E-X@D@ DC 3-Wire Models E2E-X@E@ No polarity DC 2-Wire No-polarity Models E2E-X@D1-M1J-T Early discovery of problems Diagnostic Models E2E-X@D1S Note: Refer to Models Not Listed in this Catalog for Long Body Models, Transmission Couplers, and Power Couplers. 3 E2E E2E Model Number Legend E2E- A B C D E F G - H I - J - K - L No. A Classification Appearance B Sensing distance C Shielding D Power supply and output specifications E Form of output switching element F Oscillation frequency type G Self-diagnosis Code X Number R Blank M B C D E F T Y 1 2 Blank 5 Blank 5 Blank H Connection method Connector specifications M3 M8-size metal connector J GJ TJ TGJ J DC 2-wire polarity K Cable specifications New model Blank T Blank R U Standard-certified model M Cable length Example: 1R5: 1.5 mm Whether D models have polarity is defined by number J. Used to prevent mutual interference. Connector Model DC 3-wire and AC 2-wire, DC 2-wire with self-diagnosis output, DC 2-wire with old pin arrangement Connector Model DC 2-wire with IEC pin arrangement Pre-wired Connector Model DC 3-wire and AC 2-wire, DC 2-wire with old pin arrangement Pre-wired Connector Model DC 2-wire with IEC pin arrangement Pre-wired Smartclick Connector Model DC 2-wire Pre-wired Smartclick Connector Model DC 2-wire with IEC pin arrangement Polarity No polarity Standard PVC cable (oil resistant) Flexible PVC cable (oil resistant) Polyurethane cable (oil resistant and reinforced) N New model (Applies only to DC 2-wire pre-wired and shielded models.) US UL-recognized model (Applies to DC 2-wire pre-wired models and pre-wired connector models.) Letter M Cable length (Unit: m) (Applicable to Pre-wired Models and Prewired Connector Models.) L Remarks Pre-wired M12-size metal connector G I Cylindrical (threaded) Sensing distance (Unit: mm) Indication of decimal point Shielded Model Unshielded Model DC 3-wire PNP open-collector output DC 3-wire NPN open-collector output DC 2-wire polarity/no polarity DC 3-wire NPN collector load built-in output DC 3-wire PNP collector load built-in output AC/DC 2-wire AC 2-wire Normally open (NO) Normally closed (NC) Standard frequency Different frequency No Yes M1 Blank M Meaning This is blank if the cable specification in number K is R or U. Example: 2M 0.3M Note: The purpose of this model number legend is to provide understanding of the meaning of specifications from the model number. Models are not available for all combinations of code numbers. 4 E2E Ordering Information 2-Wire Models Shielded DC 2-wire Models with No Self-diagnostic Output [Refer to Dimensions on page 27.] Appearance Sensing distance Connection method Cable specifications Polarity M12 Pre-wired Smart- PUR (increased click Connector Mod- oil-resistant) els (0.3m) PVC (oil-resistant) M8 2 mm Pre-wired Models (2 m) PUR (increased oil-resistant) PVC (oil-resistant) M12 Connector Models M8 Connector Models Yes --- M12 Pre-wired Smart- PUR (increased click Connector Mod- oil-resistant) els (0.3m) PVC (oil-resistant) Pre-wired Models (2 m) M12 Yes M12 Connector Models Yes No *3 M12 Pre-wired Smart- PUR (increased click Connector Mod- oil-resistant) els (0.3m) PVC (oil-resistant) Pre-wired Models (2 m) M18 PUR (increased oil-resistant) Yes M12 Connector Models Yes No *3 M12 Pre-wired Smart- PUR (increased click Connector Mod- oil-resistant) els (0.3m) PVC (oil-resistant) Pre-wired Models (2 m) M30 PUR (increased oil-resistant) Yes M12 Connector Models M12 Standard Prewired Connector Mod- PVC (oil-resistant) els (0.3 m) Yes No *3 E2E-X2D1-M1TGJ-U 0.3M E2E-X2D2-M1TGJ-U 0.3M E2E-X2D1-M1TGJ 0.3M E2E-X2D1-U 2M NC E2E-X2D2-U 2M NO --- --- E2E-X2D1-N 2M E2E-X2D2-N 2M NO 1: +V, 4: 0 V A D NC 1: +V, 2: 0 V NO 1: +V, 4: 0 V NC 1: +V, 2: 0 V NO 1: +V, 4: 0 V NC 1: +V, 2: 0 V NO 1: +V, 4: 0 V I H G E2E-X2D1-M1G E2E-X2D2-M1G E2E-X2D1-M3G E2E-X2D2-M3G E2E-X3D1-M1TGJ-U 0.3M E2E-X3D2-M1TGJ-U 0.3M E2E-X3D1-M1TGJ 0.3M NO E2E-X3D1-U 2M NC E2E-X3D2-U 2M --- --- E2E-X3D1-N 2M *1 E2E-X3D2-N 2M NO 1: +V, 4: 0 V A E2E-X3D1-M1G *1 NC 1: +V, 2: 0 V D E2E-X3D2-M1G NO 1: +V, 4: 0 V A E2E-X3D1-M1GJ 0.3M NC 1: +V, 2: 0 V D E2E-X3D2-M1GJ 0.3M NO (3, 4): (+V, 0 V) C E2E-X3D1-M1J-T 0.3M NC (1, 2): (+V, 0 V) D NO 1: +V, 4: 0 V NC 1: +V, 2: 0 V NO 1: +V, 4: 0 V H G --E2E-X7D1-M1TGJ-U 0.3M E2E-X7D2-M1TGJ-U 0.3M E2E-X7D1-M1TGJ 0.3M NO E2E-X7D1-U 2M NC E2E-X7D2-U 2M --- --- E2E-X7D1-N 2M *1 E2E-X7D2-N 2M NO 1: +V, 4: 0 V A E2E-X7D1-M1G *1 NC 1: +V, 2: 0 V D E2E-X7D2-M1G NO 1: +V, 4: 0 V A E2E-X7D1-M1GJ 0.3M NC 1: +V, 2: 0 V D E2E-X7D2-M1GJ 0.3M NO (3, 4): (+V, 0 V) C E2E-X7D1-M1J-T 0.3M NC (1, 2): (+V, 0 V) D E2E-X7D2-M1J-T 0.3M NO 1: +V, 4: 0 V NC 1: +V, 2: 0 V NO 1: +V, 4: 0 V H G E2E-X10D1-M1TGJ-U 0.3M E2E-X10D2-M1TGJ-U 0.3M E2E-X10D1-M1TGJ 0.3M NO E2E-X10D1-U 2M NC E2E-X10D2-U 2M --- --- NC --- Model NO NO PVC (oil-resistant) 10 mm G NC --- M12 Standard Prewired Connector Mod- PVC (oil-resistant) els (0.3 m) 1: +V, 4: 0 V NO PVC (oil-resistant) 7 mm NO H NC --- M12 Standard Prewired Connector Mod- PVC (oil-resistant) els (0.3 m) 1: +V, 2: 0 V NO PVC (oil-resistant) 3 mm NC Applicable connector code *2 NC --- PUR (increased oil-resistant) OperaPin tion arrangement mode NO 1: +V, 4: 0 V E2E-X10D1-N 2M *1 E2E-X10D2-N 2M NO 1: +V, 4: 0 V A E2E-X10D1-M1G *1 NC 1: +V, 2: 0 V D E2E-X10D2-M1G NO 1: +V, 4: 0 V A E2E-X10D1-M1GJ 0.3M NC 1: +V, 2: 0 V D E2E-X10D2-M1GJ 0.3M NO (3, 4): (+V, 0 V) C E2E-X10D1-M1J-T 0.3M NC (1, 2): (+V, 0 V) D E2E-X10D2-M1J-T 0.3M *1. Models with different frequencies are also available. The model number is E2E-X @D15 (example: E2E-X3D15-N 2M). *2. Refer to page 22 for details. *3. The residual voltage for models without polarity is 5 V, so use caution concerning the connection load interface conditions (e.g., PLC ON voltage). Refer to page 26 5 E2E 2-Wire Models Shielded DC 2-Wire UL-recognized Models with No Self-diagnostic Output [Refer to Dimensions on page 27.] Appearance M8 Sensing distance 2 mm Connection method Cable specifications Polarity M12 Pre-wired Smartclick Connector Models (0.3 m) 3 mm M18 7 mm Pre-wired Models (2 m) M30 10 mm M12 Pre-wired Smartclick Connector Models (0.3 m) Pre-wired Models (2 m) 1: +V, 2: 0 V PVC (oil-resistant) Yes --- NO 1: +V, 4: 0 V NC 1: +V, 2: 0 V NO Pre-wired Models (2 m) M12 Pre-wired Smartclick Connector Models (0.3 m) 1: +V, 4: 0 V NC NC M12 Pre-wired Smartclick Connector Models (0.3 m) Pin arrangement NO NO Pre-wired Models (2 m) M12 Operation mode NC --- NO 1: +V, 4: 0 V NC 1: +V, 2: 0 V NO NC --- NO 1: +V, 4: 0 V NC 1: +V, 2: 0 V NO NC --- Applicable connector code * Model E2E-X2D1-M1TGJ-US 0.3M G --- E2E-X2D2-M1TGJ-US 0.3M E2E-X2D1-US 2M E2E-X2D2-US 2M E2E-X3D1-M1TGJ-US 0.3M G --- E2E-X3D2-M1TGJ-US 0.3M E2E-X3D1-US 2M E2E-X3D2-US 2M E2E-X7D1-M1TGJ-US 0.3M G --- E2E-X7D2-M1TGJ-US 0.3M E2E-X7D1-US 2M E2E-X7D2-US 2M E2E-X10D1-M1TGJ-US 0.3M G --- E2E-X10D2-M1TGJ-US 0.3M E2E-X10D1-US 2M E2E-X10D2-US 2M * Refer to page 22 for details. 6 E2E 2-Wire Models Unshielded DC 2-Wire Models with No Self-diagnosis Output [Refer to Dimensions on page 27.] Appearance Sensing distance Connection method Cable specifications Polar- Operation ity mode NO Pre-wired Models (2 m) PVC (oil-resistant) M8 M12 Connector Models 4 mm NC --- M8 Connector Models --- M12 Pre-wired Smartclick Connector Models (0.3m) PVC (oil-resistant) M12 M12 Connector Models --- M12 Standard Prewired Connector Models (0.3 m) PVC (oil-resistant) M12 Pre-wired Smartclick Connector Models (0.3m) PVC (oil-resistant) Pre-wired Models (2 m) PVC (oil-resistant) M18 14 mm M12 Connector Models --- M12 Standard Prewired Connector Models (0.3 m) PVC (oil-resistant) M12 Pre-wired Smartclick Connector Models (0.3m) PVC (oil-resistant) Pre-wired Models (2 m) PVC (oil-resistant) M30 20 mm M12 Connector Models M12 Standard Prewired Connector Models (0.3 m) --PVC (oil-resistant) Yes --- --- 1: +V, 4: 0 V A NC 1: +V, 2: 0 V D NO 1: +V, 4: 0 V NC 1: +V, 2: 0 V NO 1: +V, 4: 0 V NC 8 mm Applicable connector code *2 NO NO Pre-wired Models (2 m) PVC (oil-resistant) Pin arrangement --- I G --- Model E2E-X4MD1 2M E2E-X4MD2 2M E2E-X4MD1-M1G E2E-X4MD2-M1G E2E-X4MD1-M3G E2E-X4MD2-M3G E2E-X8MD1-M1TGJ 0.3M E2E-X8MD1 2M *1 E2E-X8MD2 2M NO 1: +V, 4: 0 V A E2E-X8MD1-M1G *1 NC 1: +V, 2: 0 V D E2E-X8MD2-M1G NO 1: +V, 4: 0 V A E2E-X8MD1-M1GJ 0.3M NC 1: +V, 2: 0 V D --- NO 1: +V, 4: 0 V G E2E-X14MD1-M1TGJ 0.3M NO NC --- --- E2E-X14MD1 2M *1 E2E-X14MD2 2M NO 1: +V, 4: 0 V A E2E-X14MD1-M1G *1 NC 1: +V, 2: 0 V D E2E-X14MD2-M1G NO 1: +V, 4: 0 V A E2E-X14MD1-M1GJ 0.3M NC 1: +V, 2: 0 V D E2E-X14MD2-M1GJ 0.3M NO 1: +V, 4: 0 V G E2E-X20MD1-M1TGJ 0.3M NO NC --- --- E2E-X20MD1 2M *1 E2E-X20MD2 2M NO 1: +V, 4: 0 V A E2E-X20MD1-M1G *1 NC 1: +V, 2: 0 V D E2E-X20MD2-M1G NO 1: +V, 4: 0 V A E2E-X20MD1-M1GJ 0.3M NC 1: +V, 2: 0 V D --- *1. Models with different frequencies are also available. The model number is E2E-X @D15 (example: E2E-X8MD15 2M). *2. Refer to page 22 for details. 7 E2E 2-Wire Models Unshielded DC 2-Wire UL-recognized Models with No Self-diagnostic Output [Refer to Dimensions on page 27.] Appearance M8 Sensing distance Connection method Cable specifications Polarity Operation mode M12 Pre-wired Smartclick Connector Models (0.3 m) 4 mm M12 14 mm M18 PVC (oil-resistant) 20 mm 1: +V, 4: 0 V NC 1: +V, 2: 0 V 1: +V, 4: 0 V NC 1: +V, 2: 0 V NC --- NO 1: +V, 4: 0 V NC 1: +V, 2: 0 V NO Pre-wired Models (2 m) --- NO NO M12 Pre-wired Smartclick Connector Models (0.3 m) --- NO NC Yes Pre-wired Models (2 m) M30 1: +V, 2: 0 V NO Pre-wired Models (2 m) M12 Pre-wired Smartclick Connector Models (0.3 m) 1: +V, 4: 0 V NC NC M12 Pre-wired Smartclick Connector Models (0.3 m) 8 mm NO NO Pre-wired Models (2 m) Pin arrangement NC --- Applicable connector code * Model E2E-X4MD1-M1TGJ-US 0.3M G --- E2E-X4MD2-M1TGJ-US 0.3M E2E-X4MD1-US 2M E2E-X4MD2-US 2M E2E-X8MD1-M1TGJ-US 0.3M G --- E2E-X8MD2-M1TGJ-US 0.3M E2E-X8MD1-US 2M E2E-X8MD2-US 2M E2E-X14MD1-M1TGJ-US 0.3M G --- E2E-X14MD2-M1TGJ-US 0.3M E2E-X14MD1-US 2M E2E-X14MD2-US 2M E2E-X20MD1-M1TGJ-US 0.3M G --- E2E-X20MD2-M1TGJ-US 0.3M E2E-X20MD1-US 2M E2E-X20MD2-US 2M * Refer to page 22 for details. Shielded DC 2-Wire Models with Self-diagnosis Output [Refer to Dimensions on page 27.] Appearance M12 Sensing distance 3 mm 7 mm 10 mm Model PVC (oil-resistant) --- --- E2E-X3D1S 2M *1 --- 2: +V and diagnostic output 3: 0 V 4: +V and control output D E2E-X3D1S-M1 Pre-wired Models (2 m) M12 Connector Models M12 Connector Models Pre-wired Models (2 m) M30 Applicable connector code *2 Cable specifications Pre-wired Models (2 m) M18 Pin arrangement Connection method M12 Connector Models Polarity Operation mode PVC (oil-resistant) --- --- E2E-X7D1S 2M *1 --- 2: +V and diagnostic output 3: 0 V 4: +V and control output D E2E-X7D1S-M1 PVC (oil-resistant) --- --- E2E-X10D1S 2M *1 --- 2: +V and diagnostic output 3: 0 V 4: +V and control output D E2E-X10D1S-M1 Yes NO *1. Models with different frequencies are also available. The model number is E2E-X @D15S (example: E2E-X3D15S 2M). *2. Refer to page 22 for details. 8 E2E 2-Wire Models Unshielded DC 2-Wire Models with Self-diagnosis Output [Refer to Dimensions on page 27.] Appearance Sensing distance 8 mm M12 14 mm M18 20 mm M30 Pin arrangement Applicable connector code *2 Model PVC (oil-resistant) --- --- E2E-X8MD1S 2M *1 M12 Connector Models --- 2: +V and diagnostic output 3: 0 V 4: +V and control output D E2E-X8MD1S-M1 Pre-wired Models (2 m) PVC (oil-resistant) --- --- E2E-X14MD1S 2M *1 2: +V and diagnostic output 3: 0 V 4: +V and control output D E2E-X14MD1S-M1 Connection method Cable specifications Pre-wired Models (2 m) Polarity Yes Operation mode NO M12 Connector Models --- Pre-wired Models (2 m) PVC (oil-resistant) --- --- E2E-X20MD1S 2M *1 --- 2: +V and diagnostic output 3: 0 V 4: +V and control output D E2E-X20MD1S-M1 M12 Connector Models *1. Models with different frequencies are also available. The model number is E2E-X @MD15S (example: E2E-X8MD15S 2M). *2. Refer to page 22 for details. Connector Pin Assignments of DC 2-Wire Models * The connector pin assignments of each New E2E DC 2-Wire Model conform to IEC 947-5-2 Table III. (Only DC 2-Wire Models have been changed in comparison to the previous models.) * The following models with conventional connector pin assignments are available as well. (Only NO Models can be used.) The cable at the right should also be used if the XW3A-P@45-G11 Connector Junction Box is already being used. Cable length 500 mm Model XS2W-D421-BY1 Internal Wiring (Proximity Sensor end) (Wired end) 1 4 4 3 Models with conventional connector pin assignments are available as well. Appearance Shielded Unshielded NO Model Applicable connector code * NC Applicable connector code * M8 E2E-X2D1-M1 C E2E-X2D2-M1 D M12 E2E-X3D1-M1 C E2E-X3D2-M1 D M18 E2E-X7D1-M1 C E2E-X7D2-M1 D M30 E2E-X10D1-M1 C E2E-X10D2-M1 D M8 E2E-X4MD1-M1 C E2E-X4MD2-M1 D M12 E2E-X8MD1-M1 C E2E-X8MD2-M1 D M18 E2E-X14MD1-M1 C E2E-X14MD2-M1 D M30 E2E-X20MD1-M1 C E2E-X20MD2-M1 D * Refer to page 22 for details. 9 E2E 2-Wire Models AC 2-Wire Models Shielded Models [Refer to Dimensions on page 27.] Appearance M8 M12 M18 Sensing distance Connection method Pre-wired Models (2 m) 1.5 mm Pre-wired Models (2 m) 2 mm M12 Connector Models Pre-wired Models (2 m) 5 mm M12 Connector Models Pre-wired Models (2 m) M30 10 mm M12 Connector Models Cable specifications PVC (oil-resistant) PVC (oil-resistant) --PVC (oil-resistant) --PVC (oil-resistant) --- Operation mode NO NC NO NC Pin arrangement Applicable connector code *2 --- --- --- --- Model E2E-X1R5Y1 2M E2E-X1R5Y2 2M E2E-X2Y1 2M *1 E2E-X2Y2 2M NO (3, 4): (AC, AC) E E2E-X2Y1-M1 NC (1, 2): (AC, AC) F E2E-X2Y2-M1 NO NC --- --- E2E-X5Y1 2M *1 E2E-X5Y2 2M NO (3, 4): (AC, AC) E E2E-X5Y1-M1 NC (1, 2): (AC, AC) F E2E-X5Y2-M1 NO NC --- --- E2E-X10Y1 2M *1 E2E-X10Y2 2M NO (3, 4): (AC, AC) E E2E-X10Y1-M1 NC (1, 2): (AC, AC) F E2E-X10Y2-M1 *1. Models with different frequencies are also available. The model number is E2E-X @Y@5 (example: E2E-X5Y15 2M). *2. Refer to page 22 for details. Unshielded Models Appearance M8 M12 M18 Sensing distance Connection method Pre-wired Models (2 m) 2 mm Pre-wired Models (2 m) 5 mm M12 Connector Models Pre-wired Models (2 m) 10 mm M12 Connector Models Pre-wired Models (2 m) M30 18 mm M12 Connector Models Cable specifications PVC (oil-resistant) PVC (oil-resistant) --PVC (oil-resistant) --PVC (oil-resistant) --- Operation mode NO NC NO NC Pin arrangement Applicable connector code *2 --- --- --- --- NO (3, 4): (AC, AC) E NC (1, 2): (AC, AC) F NO NC --(3, 4): (AC, AC) E NC (1, 2): (AC, AC) F NO NC --- E2E-X2MY2 2M E2E-X5MY1 2M *1 E2E-X5MY2 2M E2E-X5MY1 2M E2E-X5MY2-M1 --- NO Model E2E-X2MY1 2M E2E-X10MY1 2M *1 E2E-X10MY2 2M E2E-X10MY1-M1 E2E-X10MY2-M1 --- E2E-X18MY1 2M *1 E2E-X18MY2 2M NO (3, 4): (AC, AC) E E2E-X18MY1-M1 NC (1, 2): (AC, AC) F E2E-X18MY2-M1 *1. Models with different frequencies are also available. The model number is E2E-X @MY@5 (example: E2E-X5MY15 2M). *2. Refer to page 22 for details. AC 2-Wire Models Shielded Models [Refer to Dimensions on page 27.] (There are no unshielded models.) Appearance M12 M18 M30 Sensing distance 3 mm 7 mm 10 mm Connection method Cable specifications Pre-wired Models (2 m) PVC (oil-resistant) Pre-wired Models (2 m) PVC (oil-resistant) Pre-wired Models (2 m) PVC (oil-resistant) Operation mode NO Pin arrangement Applicable connector code --- --- E2E-X3T1 2M --- --- E2E-X7T1 2M --- --- E2E-X10T1 2M Model 10 E2E 3-Wire Models Shielded DC 3-Wire Models [Refer to Dimensions on page 27.] Appearance Sensing distance Connection method Pre-wired Models (2 m) M8 1.5 mm 2 mm 10 mm PVC (oil-resistant) NC --- M12 Connector Models Pre-wired Models (2 m) M30 NO M8 Connector Models M12 Connector Models 5 mm PVC (oil-resistant) --- Pre-wired Models (2 m) M18 Operation mode M12 Connector Models Pre-wired Models (2 m) M12 Cable specifications M12 Connector Models PVC (oil-resistant) --- --- Model NPN output PNP output E2E-X1R5E1 2M E2E-X1R5F1 2M E2E-X1R5E2 2M E2E-X1R5F2 2M NO B E2E-X1R5E1-M1 E2E-X1R5F1-M1 NC 1: +V, 3: 0 V, 2: Control output D E2E-X1R5E2-M1 E2E-X1R5F2-M1 NO 1: +V, 3: 0 V, 4: Control output E2E-X1R5E1-M3 E2E-X1R5F1-M3 NC 1: +V, 3: 0 V, 2: Control output E2E-X1R5E2-M3 E2E-X1R5F2-M3 NO I E2E-X2E1 2M *1 E2E-X2F1 2M *1 E2E-X2E2 2M E2E-X2F2 2M B E2E-X2E1-M1 E2E-X2F1-M1 D E2E-X2E2-M1 E2E-X2F2-M1 --- --- NO 1: +V, 3: 0 V, 4: Control output NC 1: +V, 3: 0 V, 2: Control output --- --- NO 1: +V, 3: 0 V, 4: Control output NC 1: +V, 3: 0 V, 2: Control output NC NO NC --- PVC (oil-resistant) Applicable connector code *2 1: +V, 3: 0 V, 4: Control output --- PVC (oil-resistant) Pin arrangement NO E2E-X5E1 2M *1 E2E-X5F1 2M *1 E2E-X5E2 2M E2E-X5F2 2M B E2E-X5E1-M1 E2E-X5F1-M1 D E2E-X5E2-M1 E2E-X5F2-M1 E2E-X10E1 2M *1 E2E-X10F1 2M E2E-X10E2 2M E2E-X10F2 2M --- --- NO 1: +V, 3: 0 V, 4: Control output B E2E-X10E1-M1 E2E-X10F1-M1 NC 1: +V, 3: 0 V, 2: Control output D E2E-X10E2-M1 E2E-X10F2-M1 NC --- *1. Models with different frequencies are also available. The model number is E2E-X@@@5 (example: E2E-X5E15 2M). *2. Refer to page 22 for details. 11 E2E 3-Wire Models Unshielded DC 3-Wire Models [Refer to Dimensions on page 27.] Appearance Sensing distance Connection method Pre-wired Models (2 m) M8 2 mm 5 mm --- M8 Connector Models --- M12 Connector Models Pre-wired Models (2 m) M18 10 mm M12 Connector Models Pre-wired Models (2 m) M30 PVC (oil-resistant) M12 Connector Models Pre-wired Models (2 m) M12 Cable specifications Applicable connector code *2 --- --- NO 1: +V, 3: 0 V, 4: Control output NC 1: +V, 3: 0 V, 2: Control output NO 1: +V, 3: 0 V, 4: Control output NO NC NC PVC (oil-resistant) NO PVC (oil-resistant) NPN output PNP output E2E-X2ME1 2M E2E-X2MF1 2M E2E-X2ME2 2M E2E-X2MF2 2M B E2E-X2ME1-M1 E2E-X2MF1-M1 D E2E-X2ME2-M1 E2E-X2MF2-M1 E2E-X2ME1-M3 E2E-X2MF1-M3 E2E-X2ME2-M3 E2E-X2MF2-M3 I E2E-X5ME1 2M *1 E2E-X5MF1 2M E2E-X5ME2 2M E2E-X5MF2 2M --- NO 1: +V, 3: 0 V, 4: Control output B E2E-X5ME1-M1 E2E-X5MF1-M1 NC 1: +V, 3: 0 V, 2: Control output D E2E-X5ME2-M1 E2E-X5MF2-M1 --- --- NO 1: +V, 3: 0 V, 4: Control output NC NO NC E2E-X10ME1 2M *1 E2E-X10MF1 2M E2E-X10ME2 2M E2E-X10MF2 2M B E2E-X10ME1-M1 E2E-X10MF1-M1 1: +V, 3: 0 V, 2: Control output D E2E-X10ME2-M1 E2E-X10MF2-M1 --- --- NO 1: +V, 3: 0 V, 4: Control output NC 1: +V, 3: 0 V, 2: Control output --- PVC (oil-resistant) 1: +V, 3: 0 V, 2: Control output Model --- NC --- 18 mm M12 Connector Models Pin arrangement Operation mode NO NC --- E2E-X18ME1 2M *1 E2E-X18MF1 2M E2E-X18ME2 2M E2E-X18MF2 2M B E2E-X18ME1-M1 E2E-X18MF1-M1 D E2E-X18ME2-M1 E2E-X18MF2-M1 *1. Models with different frequencies are also available. The model number is E2E-X@M@@5 (example: E2E-X5ME15 2M). *2. Refer to page 22 for details. 12 E2E Ratings and Specifications E2E-X@D@ DC 2-Wire Models Size Shielded Item M8 Shielded M12 Unshielded Model E2E-X2D@ Shielded M18 Unshielded Shielded M30 Unshielded Shielded Unshielded E2E-X4MD@ E2E-X3D@ E2E-X8MD@ E2E-X7D@ E2E-X14MD@ E2E-X10D@ E2E-X20MD@ Sensing distance 2 mm 10% 4 mm 10% 3 mm 10% 8 mm 10% 7 mm 10% 14 mm 10% 10 mm 10% 20 mm 10% Set distance *1 0 to 1.6 mm 0 to 3.2 mm 0 to 2.4 mm 0 to 6.4 mm 0 to 5.6 mm 0 to 11.2 mm 0 to 8 mm 0 to 16 mm Differential travel 15% max. of sensing distance Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on pages 17 and 18. Standard sensing object Iron, 8 x 8 x 1 mm Iron, Iron, Iron, Iron, Iron, 30 x 30 x 1 mm 20 x 20 x 1 mm 12 x 12 x 1 mm 30 x 30 x 1 mm 18 x 18 x 1 mm Iron, 54 x 54 x 1 mm Response frequency *2 1.5 kHz 1 kHz 0.1 kHz Power supply voltage (operating voltage range) Standard Models: 12 to 24 VDC, ripple (p-p): 10% max. (10 to 30 VDC) US Models and Connector Models Used as UL-certified Models: 12 to 24 VDC, ripple (p-p): 10% max. (The operating voltage range is also the same.) *3 Leakage current 0.8 mA max. Control output 10% max. of sensing distance 0.8 kHz 0.5 kHz Load current 3 to 100 mA, Diagnostic output: 50 mA for -D1(5)S Models Residual voltage *4 3 V max. (Load current: 100 mA, Cable length: 2 m, M1J-T Models only: 5 V max.) 0.4 kHz Indicators D1 Models: Operation indicator (red) and setting indicator (green) D2 Models: Operation indicator (red) Operation mode (with sensing object approaching) D1 Models: NO D2 Models: NC Diagnostic output delay 0.3 to 1 s Protection circuits Surge suppressor, Load short-circuit protection (for control and diagnostic output) Ambient temperature range Operating: -25 to 70C, Storage: -40 to 85C (with no icing or condensation) Ambient humidity range Operating/storage: 35% to 95% (with no condensation) Temperature influence 15% max. of sensing distance at 23C in the temperature range of -25 to 70C Voltage influence 1% max. of sensing distance at rated voltage in the rated voltage 15% range Insulation resistance 50 M min. (at 500 VDC) between current-carrying parts and case Dielectric strength 1000 VAC, 50/60 Hz for 1 minute between current carry parts and case Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions Shock resistance Destruction: 500 m/s2 10 times each in X, Y, and Z directions Degree of protection Pre-wired Models: IEC 60529 IP67, in-house standards: oil-resistant Connector Models: IEC 60529 IP67 Connection method Pre-wired Models (Standard cable length: 2 m), Connector Models, or Pre-wired Connector Models (Standard cable length: 0.3 m) Pre-wired Models Weight Pre-wired (packConnector ed Models state) Connector Models Case Sensing surface MateriClamping als nuts Toothed washer Accessories Refer to the timing charts under I/O Circuit Diagrams on page 20 for details. Approx. 60 g 10% max. of sensing distance at 23C in the temperature range of -25 to 70C Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions Approx. 70 g Approx. 130 g Approx. 175 g Approx. 40 g Approx. 70 g Approx. 110 g Approx. 15 g Approx. 25 g Approx. 40 g Approx. 90 g Stainless steel (SUS303) Nickel-plated brass --- PBT Nickel-plated brass Zinc-plated iron Instruction manual *1. Use the E2E within the range in which the setting indicator (green LED) is ON (except D2 Models). *2. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance. *3. For the information on UL-certified connector models, refer to your OMRON website. *4. The residual voltage of each M1J-T Model is 5 V. When connecting to a device, make sure that the device can withstand the residual voltage. (Refer to page 26 for details.) 13 E2E E2E-X@Y@ AC 2-Wire Models Size Shielded Item M8 Shielded Model E2E-X1R5Y@ M12 Unshielded E2E-X2MY@ Shielded E2E-X2Y@ M18 Unshielded E2E-X5MY@ Shielded E2E-X5Y@ M30 Unshielded Shielded Unshielded E2E-X10MY@ E2E-X10Y@ E2E-X18MY@ Sensing distance 1.5 mm 10% 2 mm 10% 5 mm 10% 10 mm 10% 18 mm 10% Set distance 0 to 1.2 mm 0 to 1.6 mm 0 to 4 mm 0 to 8 mm 0 to 14 mm Differential travel 10% max. of sensing distance Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 18.) Standard sensing object Iron, 8 x 8 x 1 mm Response frequency 25 Hz Power supply voltage (operating voltage range)*1 24 to 240 VAC (20 to 264 VAC), 50/60 Hz Leakage current 1.7 mA max. Control output Iron, 12 x 12 x 1 mm Load current *2 5 to 100 mA Residual voltage Refer to Engineering Data on page 19. Iron, Iron, Iron, 30 x 30 x 1 mm 15 x 15 x 1 mm 18 x 18 x 1 mm 5 to 200 mA 5 to 300 mA Indicators Operation indicator (red) Operation mode (with sensing object approaching) Y1 Models: NO Y2 Models: NC Protection circuits Surge suppressor Ambient temperature range *1*2 Operating/Storage: -25 to 70C (with no icing or condensation) Ambient humidity range Operating/storage: 35% to 95% (with no condensation) Temperature influence 10% max. of sensing distance at 23C in the temperature range of -25 to 70C Voltage influence 1% max. of sensing distance at rated voltage in the rated voltage 15% range Insulation resistance 50 M min. (at 500 VDC) between current-carrying parts and case Dielectric strength 4,000 VAC (M8 Models: 2,000 VAC), 50/60 Hz for 1 min between current-carrying parts and case Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions Shock resistance Destruction: 500 m/s2 10 times each in X, Y, and Z directions Degree of protection Pre-wired Models: IEC 60529 IP67, in-house standards: oil-resistant Connector Models: IEC 60529 IP67 Connection method Pre-wired Models (Standard cable length: 2 m) and Connector Models Weight (packed state) Materials Accessories Iron, 54 x 54 x 1 mm Refer to the timing charts under I/O Circuit Diagrams on page 21 for details. Operating/Storage: -40 to 85C (with no icing or condensation) 15% max. of sensing distance at 23C in the temperature range of -40 to 85C, 10% max. of sensing distance at 23C in the temperature range of -25 to 70C Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions Prewired Models Model Approx. 60 g Approx. 70 g Approx. 130 g Approx. 175 g Connector Models Approx. 15 g Approx. 25 g Approx. 40 g Approx. 90 g Case Stainless steel (SUS303) Nickel-plated brass Sensing surface PBT Clamping nuts Nickel-plated brass Toothed washer Zinc-plated iron Instruction manual *1. When supplying 24 VAC to any of the above models, make sure that the operating ambient temperature range is at least -25C. *2. When using an M18 or M30 Connector Model at an ambient temperature between 70 and 85C, make sure that the Sensor has a control output (load current) of 5 to 200 mA max. 14 E2E E2E-X@T1 AC/DC 2-Wire Models Size M12 M18 E2E-X3T1 E2E-X7T1 Shielded Item M30 Shielded Model E2E-X10T1 Sensing distance 3 mm 10% 7 mm 10% 10 mm 10% Set distance 0 to 2.4 mm 0 to 5.6 mm 0 to 8 mm Differential travel 10% max. of sensing distance Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 17.) Iron, 12 x 12 x 1 mm Iron, 18 x 18 x 1 mm Iron, 30 x 30 x 1 mm DC 1 kHz 0.5 kHz 0.4 kHz AC 25 Hz Standard sensing object Response frequency *1 Power supply voltage 24 to 240 VDC (20 to 264 VDC) (operating voltage range) *2 48 to 240 VAC (40 to 264 VAC) Leakage current Control output DC: 1 mA max. AC: 2 mA max. Load current 5 to 100 mA Residual voltage DC: 6 V max. (Load current: 100 mA, Cable length: 2 m) AC: 10 V max. (Load current: 5 mA, Cable length: 2 m) Indicators Operation indicator (red), Setting indicator (green) Operation mode (with sensing object approaching) NO (Refer to the timing charts under I/O Circuit Diagrams on page 21 for details.) Protection circuits Load short-circuit protection (20 to 40 VDC only), Surge suppressor Ambient temperature range Operating: -25 to 70C, Storage: -40 to 85C (with no icing or condensation) Ambient humidity range Operating/Storage: 35% to 95% (with no condensation) Temperature influence 10% max. of sensing distance at 23C in the temperature range of -25 to 70C Voltage influence 1% max. of sensing distance at rated voltage in the rated voltage 15% range Insulation resistance 50 M min. (at 500 VDC) between current-carrying parts and case Dielectric strength 4,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions Shock resistance Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions Degree of protection IEC 60529 IP67, in-house standards: oil-resistant Connection method Pre-wired Models (Standard cable length: 2 m) Weight (packed state) Materials Accessories Approx. 80 g Case Nickel-plated brass Sensing surface PBT Clamping nuts Nickel-plated brass Toothed washer Zinc-plated iron Approx. 140 g Approx. 190 g Instruction manual *1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance. *2. Power Supply Voltage Waveform: Use a sine wave for the power supply. Using a rectangular AC power supply may result in faulty reset. 15 E2E E2E-X@E@/F@ DC 3-Wire Models Size Shielded M8 Shielded M12 Unshielded Shielded Shielded Unshielded E2E -X10ME@/F@ E2E-X10E@/ F@ E2E -X18ME@/F@ Sensing distance 1.5 mm 10% 2 mm 10% 5 mm 10% 10 mm 10% 18 mm 10% Set distance 0 to 1.2 mm 0 to 1.6 mm 0 to 4 mm 0 to 8 mm 0 to 14 mm Differential travel 10% max. of sensing distance Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 18.) Standard sensing object Iron, 8 x 8 x 1 mm Iron, 12 x 12 x 1 mm Iron, 15 x15 x 1 mm Iron, Iron, 30 x 30 x 1 mm 18 x 18 x 1 mm Iron, 54 x 54 x 1 mm Response frequency *1 2 kHz 0.8 kHz 0.4 kHz 0.6 kHz 0.1 kHz Power supply voltage (operating voltage range) *2 12 to 24 VDC, ripple(p-p): 10% max. (10 to 30 VDC) Connector Models Used as UL-certified Models: 12 to 24 VDC, ripple (p-p): 10% max. (The operating voltage range is also the same.) *3 Current consumption 13 mA max. Control output Load current *2 200 mA max. Residual voltage 2 V max. (Load current: 200 mA, Cable length: 2 m) E2E -X5E@/F@ M30 Unshielded E2E -X2ME@/F@ 1.5 kHz E2E -X5ME@/F@ Shielded E2E Model -X1R5E@/F@ Item E2E -X2E@/F@ M18 Unshielded 0.2 kHz Indicators Operation indicator (red) Operation mode (with sensing object approaching) E1/F1 Models: NO E2/F2 Models: NC Refer to the timing charts under /O Circuit Diagrams on page 21 for details. Protection circuits Load short-circuit protection, Surge suppressor, Reverse polarity protection Ambient temperature range *2 Operating/Storage: -40 to 85C (with no icing or condensation) Ambient humidity range Operating/Storage: 35% to 95% (with no condensation) Temperature influence 15% max. of sensing distance at 23C in the temperature range of -40 to 85C 10% max. of sensing distance at 23C in the temperature range of -25 to 70C Voltage influence 1% max. of sensing distance at rated voltage in the rated voltage 15% range Insulation resistance 50 M min. (at 500 VDC) between current-carrying parts and case Dielectric strength 1,000 VAC, 50/60 Hz for 1 minute between current carry parts and case Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions Shock resistance Destruction: 500 m/s2 10 times each in X, Y, and Z directions Degree of protection Pre-wired Models : IEC 60529 IP67, in-house standards: oil-resistant Connector Models : IEC 60529 IP67 Connection method Pre-wired Models (Standard cable length: 2 m) and Connector Models Weight (packed state) Materials Accessories 0.4 kHz Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions Prewired Models Approx. 65 g Approx. 75 g Approx. 150 g Approx. 195 g Connector Models Approx. 15 g Approx. 25 g Approx. 40 g Approx. 90 g Case Stainless steel (SUS303) Nickel-plated brass Sensing surface PBT Clamping nuts Nickel-plated brass Toothed washer Zinc-plated iron Instruction manual *1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance. *2. When using an M8 Model at an ambient temperature between 70 and 85C, supply 10 to 30 VDC to the Sensor and make sure that the Sensor has a control output of 100 mA maximum. *3. For the information on UL-certified connector models, refer to your OMRON website. 16 E2E Engineering Data (Reference Value) Sensing Area Shielded Models E2E-X@E@/-X@Y@/-X@F@ 12 Distance X (mm) Distance X (mm) E2E-X@D@/-X@T1 E2E-X10 10 8 E2E-X7 6 E2E-X10 10 Y 8 X 6 E2E-X3 E2E-X5 E2E-X2 Y 4 12 E2E-X2 4 X 2 0 -20 E2E -X1R5 2 -15 -10 -5 0 5 0 -15 10 15 Distance Y (mm) -10 -5 0 5 10 Distance Y (mm) Unshielded Models E2E-X@ME@/-X@MY@/-X@MF@ Distance X (mm) Distance X (mm) E2E-X@MD@ 30 25 20 30 Y X 25 20 E2E-X18M E2E -X20M 15 E2E-X10M Y 10 10 X E2E-X5M E2E -X8M 5 0 -30 15 E2E -X14M E2E-X2M 5 E2E -X4M -20 -10 0 0 -30 10 20 Distance Y (mm) -20 -10 0 10 20 Distance Y (mm) Influence of Sensing Object Size and Material E2E-X3D@/-X3T1 dx d X 2.5 t = 1 mm Iron 2.0 E2E-X7D@/-X7T1 4.0 3.5 dx d X Distance X (mm) 3.0 Distance X (mm) Distance X (mm) E2E-X2D@ t = 1 mm 3.0 Iron Stainless steel (SUS304) 1.0 Aluminum Copper 2.0 4 1.5 Brass 3 1.0 Aluminum Copper 2 5 10 15 20 25 0 5 10 dx d X 10 t = 1 mm Iron 8 6 Stainless steel (SUS304) 4 Brass Aluminum Copper 0 15 20 25 30 35 20 30 40 50 60 70 Side length of sensing object: d (mm) 0 40 10 20 E2E-X8MD@ 6 dx d X 5 t = 1 mm 4 Iron 3 Stainless steel (SUS304) 0 30 12 10 dx d X Iron 8 Stainless steel (SUS304) 4 Brass Aluminum Copper 2 10 20 30 40 50 60 70 Side length of sensing object: d (mm) 50 t = 1 mm 6 Brass Aluminum Copper 40 Side length of sensing object: d (mm) E2E-X4MD@ 1 10 Copper Side length of sensing object: d (mm) 2 2 Aluminum Distance X (mm) Distance X (mm) 12 Stainless steel (SUS304) Brass Distance X (mm) Side length of sensing object: d (mm) E2E-X10D@/-X10T1 Iron 1 0.5 0 t = 1 mm X 6 Stainless steel (SUS304) Brass 0.5 dx d 7 5 2.5 1.5 8 0 10 15 20 30 40 50 60 70 Side length of sensing object: d (mm) 17 25 dx d t = 1 mm X 20 15 E2E-X1R5E@/-X1R5Y@/-X1R5F@ 10 20 30 40 dx d X Iron 20 50 70 X t = 1 mm Iron 2.0 Stainless steel (SUS304) 1.5 t = 1 mm Stainless steel (SUS304) 1.0 Brass Aluminum Copper Brass 0 Aluminum 0.5 10 20 30 40 50 60 70 80 0 90 100 5 Side length of sensing object: d (mm) 10 15 20 E2E-X5E@/-X5Y@/-X5F@ E2E-X10E@/-X10Y@/-X10F@ 7 dx d 6 X t = 1 mm Iron 5 12 dx d X 10 t = 1 mm 8 Iron Stainless steel (SUS304) Stainless steel (SUS304) 4 25 Side length of sensing object: d (mm) Distance X (mm) 2.5 X 2.0 Distance X (mm) Distance X (mm) E2E-X2E@/-X2Y@/-X2F@ dx d Iron 5 60 2.5 1.5 Stainless steel (SUS304) Side length of sensing object: d (mm) dx d t = 1 mm 10 Stainless steel (SUS304) Brass Aluminum Copper 5 25 15 Iron 10 0 E2E-X20MD@ Distance X (mm) Distance X (mm) E2E-X14MD@ Distance X (mm) E2E 6 3 1.0 Brass Brass 2 Brass 0.5 4 Aluminum Aluminum Aluminum 2 1 5 10 15 20 0 25 10 2.5 dx d X 30 40 50 E2E-X5ME@/-X5MY@/-X5MF@ Distance X (mm) Distance X (mm) E2E-X2ME@/-X2MY@/-X2MF@ 20 t = 1 mm Iron 2.0 Stainless steel (SUS304) 1.5 0 10 Side length of sensing object: d (mm) Side length of sensing object: d (mm) 7 6 dx d 20 40 50 60 E2E-X10ME@/-X10MY@/-X10MF@ t = 1 mm X Iron 5 12 dx d X 10 t = 1 mm Iron 8 Stainless steel (SUS304) 4 30 Side length of sensing object: d (mm) Distance X (mm) 0 Stainless steel (SUS304) 6 3 Brass 1.0 Aluminum Brass 4 Aluminum 2 0.5 Aluminum 1 0 5 10 15 20 25 Brass 2 Copper 30 Side length of sensing object: d (mm) 0 10 20 30 40 50 Side length of sensing object: d (mm) 0 10 20 30 40 50 60 Side length of sensing object: d (mm) Distance X (mm) E2E-X18ME@/-X18MY@/-X18MF@ 25 dx d X t = 1 mm 20 Iron 15 Stainless steel (SUS304) 10 Brass 5 0 Aluminum 20 40 60 80 100 Side length of sensing object: d (mm) 18 E2E Leakage Current 0.8 E2E-X10D1-N 0.6 E2E-X3D1-N E2E-X@T1 Leakage current (mA) E2E-X@Y@ 1.0 Leakage current (mA) Leakage current (mA) E2E-X@D@ 1.4 1.2 1.0 0.8 1.4 1.2 AC power 1.0 0.8 DC power 0.6 0.4 E2E-X2D1-N 0.6 Protective resistance 0.4 mA 0.4 ~ E2E-X7D1-N 0.2 V ~ 0.2 AC power Proximity Sensor (OFF) 0 5 10 15 20 25 30 0 50 100 150 Power supply voltage (V) 200 0.2 250 300 0 50 100 150 Power supply voltage (V) 200 250 300 Power supply voltage (V) Residual Output Voltage E2E-X@T1 4 E2E-X@D1-M1J-T 3 E2E-X@D@ 6 24 VDC 4 3 1 2 3 5 10 30 50 100 100 VAC 5 2 0 1 200 VAC 1 3 5 10 30 30 25 20 Residual output voltage ON 15 Residual output voltage 100 ON 80 V ~ 60 5 Residual load voltage 0 1 3 5 10 30 240 Residual output voltage 200 ON 160 V ~ 120 VL VL 100 VAC A ~ 40 VL A ~ E2E-X@Y@ at 200 VAC 120 V ~ 10 100 E2E-X@Y@ at 100 VAC Load voltage VL (V) Load voltage VL (V) E2E-X@Y@ at 24 VAC 50 Load current (mA) Load current (mA) Load voltage VL (V) 5 Residual output voltage (V) Residual output voltage (V) E2E-X@D@ 200 VAC A ~ 80 24 VAC 20 OFF 50 100 300 500 Load current (mA) 40 Residual load voltage 0 1 3 5 OFF 10 30 50 100 300 500 Load current (mA) Residual load voltage 0 1 3 OFF 5 10 30 50 100 300 500 Load current (mA) 19 E2E I/O Circuit Diagrams E2E-X@D@ DC 2-Wire Models Operation mode Model Timing Chart Output circuit Polarity: Yes 1 E2E-X@D1-N E2E-X@D1-M1G(J) E2E-X@D1(-M1TGJ)-U E2E-X@D1-M3G E2E-X@D1(-M1TGJ)-US Set position Unstable Non-sensing sensing area area Stable sensing area Proximity Sensor Sensing object Without selfdiagnostic output: NO Proximity Sensor main circuit Load Brown +V 4 0V Blue Note: The load can be connected to either the +V or 0 V side. 100 80 (%) 0 Rated sensing distance Polarity: None ON Setting indicator OFF (green) 4 Load ON Operation OFF indicator (red) ON E2E-X@D1-M1J-T OFF Control output Proximity Sensor main circuit +V (0 V) 3 0V (+V) Note 1. The load can be connected to either the +V or 0 V side. 2. The E2E-X@D1-M1J-T has no polarity. Therefore, terminals 3 and 4 have no polarity. Non-sensing area Sensing area Proximity Sensor Without selfdiagnostic output: NC E2E-X@D2-N E2E-X@D2-M1G E2E-X@D2(-M1TGJ)-U E2E-X@D2-M3G E2E-X@D2(-M1TGJ)-US Sensing object 100 (%) Proximity Sensor main circuit 0 Rated sensing distance 1 Operation indicator (red) ON OFF Unstable Non-sensing sensing area area E2E-X@D1S E2E-X@D1S-M1 0V Note: The load can be connected to either the +V or 0 V side. Control output Set position Stable sensing area Proximity Sensor Sensing object With selfdiagnostic output: NO +V 2 Blue ON OFF (%) Load Brown Brown (4) 100 80 Rated sensing distance Load 0 ON OFF Setting indicator ON (green) OFF Operation ON Proximity Sensor main circuit +V Load Orange (2) (diagnostic output) +V Blue (3) indicator (red) 0 OFF Control output ON OFF Diagnostic output* Note: Connect both the loads to the +V side of the control output and diagnostic output. * The diagnostic output is ON when there is a coil burnout or the sensing object is located in the unstable sensing area for 0.3 s or longer. 20 E2E DC 3-Wire Models Operation mode Output specifications Model Timing Chart Sensing object Present Not present Operation indicator (red) NO 1 +V ON 100 OFF Control output (between brown and black leads) Output voltage (between black and blue leads) E2E-X@E@ NPN output E2E-X@E@-M1 E2E-X@E@-M3 Output circuit Brown Load ON Proximity Sensor main circuit OFF High Low Constant current* 4 2 Black Tr 3 0V Present Sensing object Blue Not present Operation indicator (red) *Constant current output is 1.5 to 3 mA. Note: For Connector Models, the connection between pins 1, 4 and 3 uses an NO contact, and the connection between pins 1, 2 and 3 uses an NC contact. ON OFF NC Control output (between brown and ON black leads) OFF Output voltage High (between black and Low blue leads) Present Sensing object 1 Not present Operation indicator (red) NO +V ON OFF Control output (Between blue and black leads) ON OFF Output voltage (between brown and black leads) E2E-X@F@ PNP output E2E-X@F@-M1 E2E-X@F@-M3 Brown High Proximity Sensor main circuit 4 2 Black Load Low 3 100 Present Sensing object Tr * Blue 0V Not present Operation indicator (red) NC ON OFF Control output (Between blue and black leads) ON OFF Output voltage (between brown and black leads) High *When a transistor is connected Note: For Connector Models, the connection between pins 1, 4 and 3 uses an NO contact, and the connection between pins 1, 2 and 3 uses an NC contact. Low AC 2-Wire Models Operation mode Model Timing Chart Sensing object NO Output circuit Present Brown 3 (or 1) Not present Load Operation indicator (red) ON Proximity Sensor main circuit OFF Operate Control output Reset E2E-X@Y@ E2E-X@Y@-M1 Present Blue 4 (or 2) Sensing object Not present ON Operation indicator (red) OFF NC Control output Note: For Connector Models, the connection between pins 3 and 4 uses an NO contact, and the connection between pins 1 and 2 uses an NC contact. Operate Reset AC/DC 2-Wire Models Operation mode Model Timing Chart Output circuit Unstable Set position Non-sensing sensing area Stable sensing area area Brown Proximity Sensor Sensing object NO E2E-X@T1 (%) 100 80 Rated sensing distance Proximity Sensor main circuit Load Power supply 24 to 240 VDC 48 to 240 VAC 0 Blue ON Setting indicator OFF (green) ON Operation OFF indicator (red) ON OFF Control output Note: The load can be connected to either the +V or 0 V side. There is no need to be concerned about the polarity (brown/blue) of the Proximity Sensor. 21 E2E Sensor I/O Connectors (Sockets on One Cable End) Model for Connectors and Pre-wired Connectors: A Connector is not provided with the Sensor. Be sure to order a Connector separately. [Refer to Dimensions for the XS2, XS3, and XS5.] Applicable connector code Screw A B Straight L-shape Straight L-shape Connector Cable length 2m CablConnector model number XS2F-D421-DA0-F XS2F-D422-DA0-F XS2F-D421-DC0-F XS2F-D422-DC0-F Cable length 5m CablConnector model number XS2F-D421-GA0-F XS2F-D422-GA0-F XS2F-D421-GC0-F XS2F-D422-GC0-F Straight XS2F-D421-DD0 XS2F-D421-GD0 L-shape XS2F-D422-DD0 XS2F-D422-GD0 Straight XS2F-D421-D80-F XS2F-D421-G80-F Appearance *1 C D M12 L-shape Straight L-shape Straight XS2F-D422-D80-F XS2F-D422-G80-F XS2F-A421-DB0-F XS2F-A422-DB0-F XS2F-A421-D90-F XS2F-A421-GB0-F XS2F-A422-GB0-F XS2F-A421-G90-F G Smartclick Connector, XS5F-D421-D80-F Straight XS5F-D421-G80-F H Smartclick Connector, Straight XS5F-D421-D80-P Oil-resistant Reinforced Cables XS5F-D421-G80-P E F Straight I XS3F-M421-402-A XS3F-M421-405-A M8 L-shape XS3F-M422-402-A XS3F-M422-405-A Applicable Proximity Sensor model number Connection diagram No. *2 E2E-X@D1-M1G(J) 1 E2E-X@E1-M1 E2E-X@F1-M1 10 E2E-X@D1-M1J-T E2E-X@D1-M1 E2E-X@D1-M1J-T E2E-X@D1-M1 E2E-X@D2-M1G(J) E2E-X@D2-M1J-T E2E-X@D2-M1 E2E-X@D1S-M1 E2E-X@E2-M1 E2E-X@F2-M1 E2E-X@D2-M1G(J) E2E-X@D2-M1J-T E2E-X@D2-M1 E2E-X@D1S-M1 E2E-X@E2-M1 E2E-X@F2-M1 3 2 3 2 6 8 7 5 11 6 8 7 5 11 E2E-X@Y1-M1 14 E2E-X@Y2-M1 E2E-X@D1-M1TGJ(-US) E2E-X@D2-M1TGJ-US 15 16 17 E2E-X@D1-M1TGJ-U 18 E2E-X@D2-M1TGJ-U 19 E2E-X@D1-M3G E2E-X@D2-M3G E2E-X@E1-M3 E2E-X@F1-M3 E2E-X@E2-M3 E2E-X@F2-M3 E2E-X@D1-M3G E2E-X@D2-M3G E2E-X@E1-M3 E2E-X@F1-M3 E2E-X@E2-M3 E2E-X@F2-M3 4 9 12 13 4 9 12 13 Note: Refer to Introduction to Sensor I/O Connectors/Sensor Controllers for details and for information on Cable length and Robotics Cables. *1. Images of straight and L-shaped connectors. M12 Straight M12 L-shape M8 Straight M8 L-shape *2. Refer to Connection Diagrams on page 23 for information on Proximity Sensor and I/O Connector connections. 22 E2E Connections for Sensor I/O Connectors Type Operation mode Model Sensor I/O Connector model number 1: Straight 2: L-shape 1 DC 2-wire (IEC pin wiring) E2E-X@D1-M1G/M1GJ XS2F-D42@-@A0-F D: 2-m cable G: 5-m cable 1: Straight 2: L-shape 2 DC 2-wire (previous pin wiring) E2E-X@D1-M1 XS2F-D42@-@D0 Connections E2E Main circuit Proximity Sensor D: 2-m cable G: 5-m cable 3 DC 2-wire (no polarity) NO E2E-X@D1-M1J-T XS2F-D42@-@D0 D: 2-m cable G: 5-m cable 4 DC 2-wire (M8 connector) E2E-X@D1-M3G XS3F-M42@-40@-A 2: 2-m cable 5: 5-m cable 5 E2E-X@D1S-M1 XS2F-D42@-@80-F D: 2-m cable G: 5-m cable 6 DC 2-wire (IEC pin wiring) E2E-X@D2-M1G/M1GJ XS2F-D42@-@80-F D: 2-m cable G: 5-m cable E2E-X@D2-M1 D: 2-m cable G: 5-m cable NC 8 DC 2-wire (no polarity) XS2F-D42@-@80-F 1: Straight 2: L-shape E2E-X@D2-M1J-T XS2F-D42@-@80-F D: 2-m cable G: 5-m cable 9 DC 2-wire (M8 connector) E2E-X@D2-M3G XS3F-M42@-40@-A 2: 2-m cable 5: 5-m cable 1 1 2 2 3 3 4 4 Blue (-) Blue (-) Brown (+) XS2F 1 1 2 2 3 3 4 4 XS3F 1 1 2 2 3 3 4 4 Blue (+) (-) Brown (-) (+) * Brown (+) White (not connected) Blue (not connected) Black (-) XS2F * 1 1 2 2 3 3 4 4 Brown (not connected) White (diagnostic output) (+) Blue (0 V) Black (control output) (+) XS2F * 1 1 2 2 3 3 4 4 Brown (+) White (-) Blue (not connected) Black (not connected) XS2F * 1 1 2 2 3 3 4 4 Brown (not connected) White (+) Blue (-) Black (not connected) XS2F * 1 1 2 2 3 3 4 4 Brown (+)(-) White (-)(+) Blue (not connected) Black (not connected) XS3F * E2E Main circuit 1: Straight 2: L-shape Brown (+) XS2F E2E Main circuit 7 4 E2E Main circuit 1: Straight 2: L-shape DC 2-wire (previous pin wiring) 4 E2E Main circuit 1: Straight 2: L-shape 3 E2E Main circuit 1: Straight 2: L-shape DC 2-wire (diagnostic type) 2 3 E2E Main circuit 1: Straight 2: L-shape 1 2 E2E Main circuit 1: Straight 2: L-shape XS2F 1 E2E Main circuit Connection diagram No. 1 1 2 2 3 3 4 4 Brown (+) White (-) Blue (not connected) Black (not connected) * Different from Proximity Sensor wire colors. 23 E2E Operation mode Model Sensor I/O Connector model number 1: Straight 2: L-shape 10 NO E2E-X@E/F1-M1 XS2F-D42@-@C0-F Connections E2E Main circuit Proximity Sensor Type D: 2-m cable G: 5-m cable DC 3-wire 1: Straight 2: L-shape 11 NC E2E-X@E2/F2-M1 XS2F-D42@-@80-F D: 2-m cable G: 5-m cable NO E2E-X@E1/F1-M3 2: 2-m cable 5: 5-m cable DC 3-wire (M8 connector) 1: Straight 2: L-shape NC 13 XS3F-M42@-40@-A E2E-X@E2/F2-M3 XS3F-M42@-40@-A 2: 2-m cable 5: 5-m cable 14 NO E2E-X@Y1-M1 XS2F-A42@-@B0-F D: 2-m cable G: 5-m cable AC 2-wire 3 4 4 1 2 2 3 3 4 4 NC E2E-X@Y2-M1 D: 2-m cable G: 5-m cable Main circuit 15 XS3F 1 2 2 3 3 4 4 NO E2E-X@D1M1TGJ(-US) D: 2-m cable G: 5-m cable Main circuit 16 1 2 2 3 3 4 4 D: 2-m cable G: 5-m cable DC 2-wire (Smartclick connector) 18 Main circuit NC XS2F 1 2 2 3 3 4 4 NO E2E-X@D1M1TGJ-U D: 2-m cable G: 5-m cable 1 2 2 3 3 4 4 NC E2E-X@D2M1TGJ-U D: 2-m cable G: 5-m cable Main circuit 19 Brown White Blue (not connected) Black (not connected) XS5F 1 1 2 2 3 3 4 4 Brown (+) White (not connected) Blue (not connected) Black (-) XS5F 1 1 2 2 3 3 4 4 Brown (+) White (-) Blue (not connected) Black (not connected) XS5F 1 1 2 2 3 3 4 4 E2E XS5F-D421-@80-P Brown Blue XS2F * 1 E2E XS5F-D421-@80-P Main circuit 17 XS5F-D421-@80-F Brown (+V) White (output) Blue (0 V) Black (not connected) 1 E2E E2E-X@D2M1TGJ-US Brown (+V) White (not connected) Blue (0 V) Black (output) XS3F 1 E2E XS5F-D421-@80-F Blue (0 V) Black (output) Brown (+V) White (not connected) Blue (0 V) Black (output) 1 E2E XS2F-A421-@90-F Brown (+V) XS3F 1 E2E Main circuit 1: Straight 2: L-shape 2 3 E2E Main circuit 12 1 2 E2E Main circuit 1: Straight 2: L-shape XS2F 1 E2E Main circuit Connection diagram No. Brown (+) White (not connected) Blue (not connected) Black (-) XS5F 1 1 2 2 3 3 4 4 Brown (+) White (-) Blue (not connected) Black (not connected) * Different from Proximity Sensor wire colors. Refer to Introduction to Sensor I/O Connectors/Sensor Controllers for details. 24 E2E Safety Precautions Refer to Warranty and Limitations of Liability. WARNING This product is not designed or rated for ensuring safety of persons either directly or indirectly. Do not use it for such purposes. CAUTION * Do not short the load. Explosion or burning may result. * Do not supply power to the Sensor with no load, otherwise Sensor may be damaged. Precautions for Correct Use Relationship between Sizes and Models Do not use this product under ambient conditions that exceed the ratings. Design Influence of Surrounding Metal Model When mounting the Sensor within a metal panel, ensure that the clearances given in the following table are maintained. Failure to maintain these distances may cause deterioration in the performance of the Sensor. Shielded M8 l Unshielded n m d dia. D m l Influence of Surrounding Metal Model Shielded DC 2-Wire Models E2E-X@D@ AC/DC 2-Wire Models E2E-X@T1 Unshielded Shielded DC 3-Wire Models E2E-X@E@ E2E-X@F@ AC 2-Wire Models E2E-X@Y@ Unshielded (Unit: mm) Item l d D m n l d D m n l d D m n l d D m n M8 M12 M18 M30 M12 0 8 12 Shielded 18 30 20 27 22 70 22 40 70 40 45 30 90 30 70 90 18 30 Unshielded 20 27 22 55 22 40 54 40 45 30 90 30 70 90 Shielded 0 4.5 12 12 24 12 8 24 8 18 15 40 15 20 40 8 12 Unshielded Shielded M18 0 0 4.5 12 6 24 6 8 24 8 18 15 40 15 20 36 M30 Unshielded Model E2E-X2D@ E2E-X1R5E@ E2E-X1R5F@ E2E-X1R5Y@ E2E-X4MD@ E2E-X2ME@ E2E-X2MF@ E2E-X2MY@ E2E-X3D@ E2E-X2E@ E2E-X2F@ E2E-X2Y@ E2E-X3T1 E2E-X8MD@ E2E-X5ME@ E2E-X5MF@ E2E-X5MY@ E2E-X7D@ E2E-X5E@ E2E-X5F@ E2E-X5Y@ E2E-X7T1 E2E-X14MD@ E2E-X10ME@ E2E-X10MF@ E2E-X10MY@ E2E-X10D@ E2E-X10E@ E2E-X10F@ E2E-X10Y@ E2E-X10T1 E2E-X20MD@ E2E-X18ME@ E2E-X18MF@ E2E-X18MY@ 25 E2E Mutual Interference Mutual Interference When installing Sensors face-to-face or side-by-side, ensure that the minimum distances given in the following table are maintained. (Unit: mm) Model DC 2-Wire Models E2E-X@D@ AC/DC 2-Wire Models E2E-X@T1 DC 3-Wire Models E2E-X@E@/X@F@ A AC 2-Wire Models E2E-X@Y@ Shielded Unshielded Shielded Unshielded Item M8 M12 M18 M30 A 20 30 (20) 50 (30) 100 (50) B 15 20 (12) * 35 (18) * 70 (35) A 80 120 (60) 200 (100) 300 (100) B 60 100 (50) 110 (60) 200 (100) A 20 30 (20) 50 (30) 100 (50) B 15 20 (12) * 35 (18) * 70 (35) A 80 120 (60) 200 (100) 300 (100) B 60 100 (50) 110 (60) 200 (100) Note: Values in parentheses apply to Sensors operating at different frequencies. * Mutual interference will not occur for close-proximity mounting if models with different frequencies are used together. B Loads with Large Surge Currents (E2E-X@T@) If a load with a large surge current is connected, such as a relay, lamp, or motor, the surge current may cause the load short-circuit protection circuit to operate, resulting in operating errors. Mounting Tightening Force Do not tighten the nut with excessive force. A washer must be used with the nut. Shielded Models Unshielded Models Part B Part A Part B Part A Note: 1. The allowable tightening strength depends on the distance from the edge of the head, as shown in the following table. (A is the distance from the edge of the head. B includes the nut on the head side. If the edge of the nut is in part A, the tightening torque for part A applies instead.) 2. The following strengths assume washers are being used. Model M8 Part A Dimension Shielded 9 Unshielded 3 M12 Part B Torque Torque 9 N*m 12 N*m 30 N*m M18 70 N*m M30 180 N*m Connecting a DC 2-Wire Proximity Sensor to a PLC (Programmable Controller) Required Conditions Connection to a PLC is possible if the specifications of the PLC and the Proximity Sensor satisfy the following conditions. (The meanings of the symbols are given at the right.) 1. The ON voltage of the PLC and the residual voltage of the Proximity Sensor must satisfy the following. VON VCC- VR 2. The OFF current of the PLC and the leakage current of the Proximity Sensor must satisfy the following. IOFF Ileak (If the OFF current is not listed in the PLC's input specifications, take it to be 1.3 mA.) 3. The ON current of the PLC and the control output of the Proximity Sensor must satisfy the following. IOUT (min.) ION IOUT (max.) The ON current of the PLC will vary, however, with the power supply voltage and the input impedance, as shown in the following equation. ION = (VCC - VR - VPC)/RIN Example In this example, the above conditions are checked when the PLC Unit is the C200H-ID212, the Proximity Sensor is the E2E-X7D1-N, and the power supply voltage is 24 V. 1. VON (14.4 V) VCc (20.4 V) - VR (3 V) = 17.4 V:OK 2. IOFF (1.3 mA) Ileak (0.8 mA): OK 3. ION = [VCC (20.4 V) - VR (3 V) - VPLC (4 V)]/RIN (3 k) = Approx. 4.5 mA Therefore, IOUT (min.) (3 mA) ION (4.5 mA): OK Connection is thus possible. VON: ON voltage of PLC (14.4 V) ION: ON current of PLC (typically 7 mA) IOFF: OFF current of PLC (1.3 mA) RIN: Input impedance of PLC (3 k) VPC: Internal residual voltage of PLC (4 V) VR: Output residual voltage of Proximity Sensor (3 V) Ileak: Leakage current of Proximity Sensor (0.8 mA) IOUT Control output of Proximity Sensor (3 to 100 mA) VCC: Power supply voltage (PLC: 20.4 to 26.4 V) Values in parentheses apply to the following PLC model and Proximity Sensor model. PLC: C200H-ID212 Sensor: E2E-X7D1-N 26 E2E (Unit: mm) Dimensions Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified. Main Units Model Number-Dimensions Drawing Number Lookup Table Model Model Shielded Shielded Pre-wired Models Unshielded Shielded Connector Models (M12) Unshielded E2E-X2D@(-US) 1 E2E-X1R5E@/F@ 1 E2E-X1R5Y@ 3 5 E2E-X2E@/F@ 5 E2E-X2Y@ 7 M18 E2E-X7D@(-US) 10 E2E-X5E@/F@ M30 E2E-X10D@(-US) M8 E2E-X4MD@(-US) M12 M18 9 10 E2E-X7T1 10 12 E2E-X10E@/F@ 12 E2E-X10Y@ 12 E2E-X10T1 12 2 E2E-X2ME@/F@ 2 E2E-X2MY@ 4 E2E-X8MD@(-US) 6 E2E-X5ME@/F@ 6 E2E-X5MY@ E2E-X14MD@(-US) 11 E2E-X10ME@/F@ 11 E2E-X10MY@ 11 M30 E2E-X20MD@(-US) 13 E2E-X18ME@/F@ 13 E2E-X18MY@ 13 M8 E2E-X2D@-M1(G) 14 E2E-X1R5E/F@-M1 14 M12 E2E-X3D@-M1(G) 16 E2E-X2E/F@-M1 16 E2E-X2Y@-M1 18 M18 E2E-X7D@-M1(G) 20 E2E-X5E/F@-M1 20 E2E-X5Y@-M1 20 M30 E2E-X10D@-M1(G) 22 E2E-X10E/F@-M1 22 E2E-X10Y@-M1 22 M8 E2E-X4MD@-M1(G) 15 E2E-X2ME/F@-M1 15 M12 E2E-X8MD@-M1(G) 17 E2E-X5ME/F@-M1 17 E2E-X5MY@-M1 19 M18 E2E-X14MD@-M1(G) 21 E2E-X10ME/F@-M1 21 E2E-X10MY@-M1 21 23 M8 M18 M30 M8 M12 M18 M30 Shielded --- 10 E2E-X5Y@ Shielded Pre-wired Connector Models (no polarity) AC/DC 2-Wire Models Model No. E2E-X3T1 M12 Unshielded AC 2-Wire Models Model No. E2E-X3D@(-US) M8 Pre-wired Connector Models DC 3-Wire Models Model No. M12 Shielded Unshielded No. M8 M30 Connector Models (M8) DC 2-Wire Models Model 8 --- E2E-X20MD@-M1(G) 23 E2E-X18ME/F@-M1 23 E2E-X18MY@-M1 24 E2E-X1R5E/F@-M3 24 E2E-X4MD@-M3G 25 E2E-X2ME/F@-M3 25 E2E-X2D@-M1(T)GJ(-U) E2E-X3D@-M1(T)GJ(-U) E2E-X3D@-M1TGJ-US E2E-X7D@-M1(T)GJ(-U) E2E-X7D@-M1TGJ-US E2E-X10D@-M1(T)GJ(-U) E2E-X10D@-M1TGJ-US E2E-X4MD@-M1TGJ-US E2E-X8MD1-M1(T)GJ E2E-X8MD@-M1TGJ-US E2E-X14MD1-M1(T)GJ E2E-X14MD@-M1TGJ-US E2E-X20MD1-M1(T)GJ E2E-X20MD@-M1TGJ-US --- --- E2E-X2D@-M3G E2E-X2D@-M1TGJ-US --- --- --- --- --- --- --- --- --- --- --- --- --- 26 27 28 29 30 31 32 33 M12 E2E-X3D1-M1J-T 27 M18 E2E-X7D@-M1J-T 28 M30 E2E-X10D@-M1J-T 29 Note 1. Two clamping nuts and one toothed washer are provided with M8 to M30 Models. 2. The model numbers of M8 to M30 Pre-wired Models are laser-marked on the milled section and cable section. This does not apply, however, to models that end in -U. 27 E2E Pre-wired Models (Shielded) Pre-wired Models (Unshielded) Diagram 1 Diagram 2 E2E-X2D@ E2E-X1R5E@/F@ 30 7 30 15 dia. 15 dia. 26 13 3 8 E2E-X2MY@ 40 13 8 7 36 15 dia. 3 *1 *1. 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: 1.3 mm), Standard length: 2 m 4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: 1.3 mm), Standard length: 2 m Robotics Cable Models: 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: 1.27 mm), Standard length: 2 m 4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: 1.27 mm), Standard length: 2 m The cable can be extended up to 200 m (separate metal conduit). *2. D1 Models: Operation indicator (red) and setting indicator (green), D2/E/F Models: Operation indicator (red) Diagram 4 36 13 Indicators *2 Two clamping nuts Toothed washer M8 x 1 7 40 8 3 6.1 dia. E2E-X1R5Y@ 15 dia. 6 *1 *1. 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: 1.3 mm), Standard length: 2 m 4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: 1.3 mm), Standard length: 2 m Robotics Cable Models: 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: 1.27 mm), Standard length: 2 m 4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: 1.27 mm), Standard length: 2 m Models with Highly Oil-resistant Cables: 4-dia. polyurethane-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: 1.3 mm), Standard length: 2 m The cable can be extended up to 200 m (separate metal conduit). *2. D1 Models: Operation indicator (red) and setting indicator (green), D2/E/F Models: Operation indicator (red) Diagram 3 7 26 13 Indicators *2 Two clamping nuts Toothed washer M8 x 1 E2E-X4MD@ E2E-X2ME@/F@ 6 8 3 6.1 dia. * Operation indicator (red) Two clamping nuts 4-dia. vinyl-insulated round cable with 2 conductors Toothed (Conductor cross section: 0.3 mm2, Insulator washer diameter: 1.3 mm), Standard length: 2 m The cable can be extended up to 200 m (separate metal conduit). M8 x 1 Diagram 5 E2E-X3D@ E2E-X2E@/F@ 38 33 21 dia. 17 Diagram 6 9 4 17 10 21 dia. Indicators *2 Two clamping nuts Toothed washer *1. 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: 1.3 mm), Standard length: 2 m 4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: 1.3 mm), Standard length: 2 m Robotics Cable Models: 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: 1.27 mm), Standard length: 2 m 4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: 1.27 mm), Standard length: 2 m The cable can be extended (separate metal conduit) up to 200 m for the control output and up to 100 m for the diagnostic output. *2. D1 Models: Operation indicator (red) and setting indicator (green), D2/E/F Models: Operation indicator (red) Diagram 8 E2E-X5MY@ 9 43 21 dia. 38 4 10 *1 E2E-X2Y@ 43 9 M12 x 1 *1. 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: 1.3 mm), Standard length: 2 m 4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: 1.3 mm), Standard length: 2 m Robotics Cable Models: 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: 1.27 mm), Standard length: 2 m 4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: 1.27 mm), Standard length: 2 m Models with Highly Oil-resistant Cables: 4-dia. polyurethane-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: 1.3 mm), Standard length: 2 m The cable can be extended (separate metal conduit) up to 200 m for the control output and up to 100 m for the diagnostic output. *2. D1 Models: Operation indicator (red) and setting indicator (green), D2/E/F Models: Operation indicator (red) 17 7 38 33 4 9 dia. *1 Diagram 7 E2E-X8MD@ E2E-X5ME@/F@ 21 dia. Indicators * 2 Two clamping nuts Toothed washer M12 x 1 * Operation indicator (red) Two clamping nuts 2 conductors Toothed 4-dia. vinyl-insulated round cable with (Conductor cross section: 0.3 mm2, Insulator diameter: washer 1.3 mm), Standard length: 2 m The cable can be extended up to 200 m (separate metal conduit). M8 x 1 10 9 38 17 7 4 10 9 dia. * M12 x 1 * Operation indicator (red) Two clamping nuts 4-dia. vinyl-insulated round cable with 2 Toothed conductors (Conductor cross section: 0.3 mm2, washer Insulator diameter: 1.3 mm), Standard length: 2 m The cable can be extended up to 200 m (separate metal conduit). M12 x 1 Operation indicator (red) Two clamping nuts Toothed 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2, washer Insulator diameter: 1.3 mm), Standard length: 2 m The cable can be extended up to 200 m (separate metal conduit). Mounting Hole Dimensions Dimension F (mm) M8 8.5 +0.5 dia. 0 M12 12.5 +0.5 dia. 0 F 28 E2E Pre-wired Models (Shielded) Diagram 9 Pre-wired Models (Unshielded) E2E-X3T1 60 21 dia. 9 55 17 4 10 --- *1 M12 x 1 Indicators *2 Two clamping nuts *1 4-dia. vinyl-insulated round cable with 2 Toothed conductors (Conductor cross section: 0.3 mm2, washer Insulator diameter: 1.3 mm), Standard length: 2 m The cable can be extended up to 200 m (separate metal conduit). *2 Operation indicator (red), Setting indicator (green) Diagram 10 E2E-X7D@/E2E-X5E@/F@ E2E-X5Y@/E2E-X7T1 43 29 dia. Diagram 11 E2E-X14MD@/E2E-X10ME@/F@ E2E-X10MY@ 43 12 29 dia. 38 10 4 24 12 38 24 4 10 10 14.8 dia. *1 Indicators *2 *1 Indicators *2 M18 x 1 Two clamping nuts Toothed washer *1. 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm), Standard length: 2 m 6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm), Standard length: 2 m Robotics Cable Models: 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2, Insulator diameter: 1.74 mm), Standard length: 2 m 6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2, Insulator diameter: 1.74 mm), Standard length: 2 m Models with Highly Oil-resistant Cables: 6-dia. polyurethane-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm), Standard length: 2 m The cable can be extended (separate metal conduit) up to 200 m for the control output and up to 100 m for the diagnostic output. *2. D1/T Models: Operation indicator (red), Setting indicator (green) D2/E/F/Y Models: Operation indicator (red) Diagram 12 E2E-X10D@/E2E-X10E@/F@ E2E-X10Y@/E2E-X10T1 48 43 42 dia. 36 5 *1 M18 x 1 Two clamping nuts Toothed washer *1. 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm), Standard length: 2 m 6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm), Standard length: 2 m Robotics Cable Models: 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2, Insulator diameter: 1.74 mm), Standard length: 2 m 6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2, Insulator diameter: 1.74 mm), Standard length: 2 m The cable can be extended (separate metal conduit) up to 200 m for the control output and up to 100 m for the diagnostic output. *2. D1/T Models: Operation indicator (red), Setting indicator (green) D2/E/F/Y Models: Operation indicator (red) Diagram 13 E2E-X20MD@/E2E-X18ME@/F@ E2E-X18MY@ 12 48 10 12 43 42 dia. 13 36 5 10 26.8 dia. *1 *1 Indicators *2 Indicators *2 M30 x 1.5 Two clamping nuts Toothed washer *1. 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm), Standard length: 2 m 6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm), Standard length: 2 m Robotics Cable Models: 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2, Insulator diameter: 1.74 mm), Standard length: 2 m 6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2, Insulator diameter: 1.74 mm), Standard length: 2 m Models with Highly Oil-resistant: 6-dia. polyurethane-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm), Standard length: 2 m The cable can be extended (separate metal conduit) up to 200 m for the control output and up to 100 m for the diagnostic output. *2. D1/T Models: Operation indicator (red), Setting indicator (green) D2/E/F/Y Models: Operation indicator (red) M30 x 1.5 Two clamping nuts Toothed washer *1. 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm), Standard length: 2 m 6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm), Standard length: 2 m Robotics Cable Models: 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2, Insulator diameter: 1.74 mm), Standard length: 2 m 6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2, Insulator diameter: 1.74 mm), Standard length: 2 m The cable can be extended (separate metal conduit) up to 200 m for the control output and up to 100 m for the diagnostic output. *2. D1/T Models: Operation indicator (red), Setting indicator (green) D2/E/F/Y Models: Operation indicator (red) Mounting Hole Dimensions Dimension F (mm) M12 M18 M30 12.5 +00.5 dia. 18.5 +00.5 dia. 30.5 +00.5 dia. F 29 E2E M8 Connector Models (Shielded) M8 Connector Models (Unshielded) Diagram 24 E2E-X2D@-M3G/E2E-X1R5E@-M3/X1RF@-M3 Diagram 25 E2E-X4MD@-M3G/E2E-X2ME@-M3/X2MF@-M3 39 39 31 15 dia. 26 8 3 13 31 15 dia. M8 x 1 26 6 13 Operation indicator (red), Setting indicator (green) D2/E/F Models: Operation indicator (red) M8 x 1 8 3 * D Models: M8 x 1 * D Models: Operation indicator (red), Setting indicator (green) D2/E/F Models: Operation indicator (red) 6.1 dia. Indicators* Two clamping nuts Toothed washer M8 x 1 Indicators* Two clamping nuts Toothed washer M12 Connector Models (Shielded) M12 Connector Models (Unshielded) Diagram 14 E2E-X2D@-M1(G) E2E-X1R5E@-M1/E2E-X1R5F@-M1 Diagram 15 E2E-X4MD@-M1(G) E2E-X2ME@-M1/E2E-X2MF@-M1 43 43 30 15 dia. 26 M12 x 1 8 3 13 30 15 dia. 26 M12 x 1 8 3 6 13 6.1 dia. M8 x 1 Indicators* Two clamping nuts Toothed washer Indicators* Two clamping nuts Toothed washer M8 x 1 * D1 Models: Operation indicator (red), Setting indicator (green) D2/E/F Models: Operation indicator (red) Diagram 16 E2E-X3D@-M1(G) E2E-X2E@-M1/E2E-X2F@-M1 * D1 Models: Operation indicator (red), Setting indicator (green) D2/E/F Models: Operation indicator (red) Diagram 17 E2E-X8MD@-M1(G) E2E-X5ME@-M1/E2E-X5MF@-M1 48 21 dia. 48 21 dia. 33 4 17 10 M12 x 1 33 7 17 M12 x 1 10 4 9 dia. Indicators * Two clamping nuts Toothed washer M12 x 1 * D1 Models: Operation indicator (red), Setting indicator (green) D2/E/F Models: Operation indicator (red) Diagram 18 E2E-X2Y@-M1 Indicators* Two clamping nuts Toothed washer M12 x 1 * D1 Models: Operation indicator (red), Setting indicator (green) D2/E/F Models: Operation indicator (red) Diagram 19 E2E-X5MY@-M1 53 53 21 dia. 21 dia. 38 4 17 10 M12 x 1 38 7 17 4 10 M12 x 1 9 dia. M12 x 1 Operation indicator (red) Two clamping nuts Toothed washer M12 x 1 Operation indicator (red) Two clamping nuts Toothed washer 30 E2E Diagram 20 E2E-X7D@-M1(G)/E2E-X5E@-M1/X5F@-M1 E2E-X5Y@-M1 53 29 dia. Diagram 21 E2E-X14MD@-M1(G)/E2E-X10ME@-M1 X10MF@-M1 E2E-X10MY@-M1 53 38 4 24 38 29 dia. 10 M12 x 1 10 24 10 4 M12 x 1 14.8 dia. Indicators* M18 x 1 * D1 Models: Two clamping nuts Toothed washer Operation indicator (red), Setting indicator (green) D2/E/Y Models: Operation indicator (red) Diagram 22 E2E-X10D@-M1(G)/E2E-X10E@-M1/X10F@-M1 E2E-X10Y@-M1 58 42 dia. 5 Two clamping nuts Toothed washer * D1 Models: Operation indicator (red), Setting indicator (green) D2/E/Y Models: Operation indicator (red) Diagram 23 E2E-X20MD@-M1(G)/E2E-X18ME@-M1/ X18MF@-M1 E2E-X18MY@-M1 58 43 36 Indicators* M18 x 1 42 dia. 10 43 13 36 5 10 26.8 dia. M12 x 1 Indicators* M30 x 1.5 M12 x 1 Indicators* Two clamping nuts M30 x 1.5 Toothed washer * D1 Models: Operation indicator (red), Setting indicator (green) D2/E/Y Models: Operation indicator (red) Two clamping nuts Toothed washer * D1 Models: Operation indicator (red), Setting indicator (green) D2/E/Y Models: Operation indicator (red) Mounting Hole Dimensions Dimensions F (mm) M8 M12 M18 M30 8.5 +00.5 dia. 12.5 +00.5 dia. 18.5 +00.5 dia. 30.5 +00.5 dia. F 31 E2E Pre-wired Connector Models (Shielded) Diagram 26 E2E-X2D@-M1TGJ-U *3 E2E-X2D1-M1TGJ E2E-X2D@-M1TGJ-US 30 15 dia. 7 26 8 13 3 *1 Indicators *2 M12 x 1 Two clamping nuts *1. No U suffix: 4-dia. Vinyl-insulated round cable Toothed washer M8 x 1 U suffix: 4-dia. Polyurethane insulated round cable, Standard length: 300 mm *2. D1 Models: Operation indicator (red), Setting indicator (green) D2 Models: Operation indicator (red) *3. The connectors for M1TGJ models are XS5 Smartclick connectors. Diagram 27 E2E-X3D@-M1GJ E2E-X3D1-M1J-T E2E-X3D@-M1TGJ-U *3 E2E-X3D1-M1TGJ E2E-X3D@-M1TGJ-US 38 21 dia. 9 33 10 4 17 *1 Indicators *2 M12 x 1 Two clamping nuts *1. No U suffix: 4-dia. Vinyl-insulated round cable U suffix: 4-dia. Polyurethane insulated round cable, Toothed washer M12 x 1 Standard length: 300 mm *2. D1 Models: Operation indicator (red), Setting indicator (green) D2 Models: Operation indicator (red) *3. The connectors for M1TGJ models are XS5 Smartclick connectors. Diagram 28 E2E-X7D@-M1GJ E2E-X7D@-M1J-T E2E-X7D@-M1TGJ-U *3 E2E-X7D1-M1TGJ E2E-X7D@-M1TGJ-US 43 29 dia. 12 38 10 4 24 *1 M12 x 1 Indicators *2 Two clamping nuts *1. No U suffix: 6-dia. Vinyl-insulated round cable U suffix: 6-dia. Polyurethane insulated round cable, Toothed washer Standard length: 300 mm M18 x 1 *2. D1 Models: Operation indicator (red), Setting indicator (green) D2 Models: Operation indicator (red) *3. The connectors for M1TGJ models are XS5 Smartclick connectors. Diagram 29 E2E-X10D@-M1GJ E2E-X10D@-M1J-T E2E-X10D@-M1TGJ-U *3 E2E-X10D1-M1TGJ E2E-X10D@-M1TGJ-US 48 42 dia. 12 43 36 5 10 *1 Indicators *2 M30 x 1.5 Two clamping nuts Toothed washer M12 x 1 *1. No U suffix: 6-dia. Vinyl-insulated round cable U suffix: 6-dia. Polyurethane insulated round cable, Standard length: 300 mm *2. D1 Models: Operation indicator (red), Setting indicator (green) D2 Models: Operation indicator (red) *3. The connectors for M1TGJ models are XS5 Smartclick connectors. 32 E2E Pre-wired Connector Models (Unshielded) Diagram 30 E2E-X4MD@-M1TGJ-US 30 15 dia. 7 26 13 6 8 3 6.1 dia. *1 Indicators *2 Two clamping nuts Toothed washer M8 x 1 Diagram 31 E2E-X8MD1-M1GJ E2E-X8MD1-M1TGJ E2E-X8MD@-M1TGJ-US 38 21 dia. M12x1 *1. 4-dia. vinyl-insulated round cable Standard length: 300 mm *2. D1 Models: Operation indicator (red), Setting indicator (green) D2 Models: Operation indicator (red) 9 33 10 4 7 17 9 dia. *1 Indicators *2 Two clamping nuts Toothed washer M12 x 1 Diagram 32 E2E-X14MD@-M1GJ E2E-X14MD1-M1TGJ E2E-X14MD@-M1TGJ-US 43 M12 x 1 *1. 4-dia. vinyl-insulated round cable, Standard length: 300 mm *2. D1 Models: Operation indicator (red), Setting indicator (green) D2 Models: Operation indicator (red) 12 38 29 dia. 10 4 10 24 14.8 dia. *1 M18 x 1 Diagram 33 E2E-X20MD1-M1GJ E2E-X20MD1-M1TGJ E2E-X20MD@-M1TGJ-US Two clamping nuts Toothed washer 48 42 dia. M12 x 1 Indicators*2 *1. 6-dia. vinyl-insulated round cable, Standard length: 300 mm *2. D1 Models: Operation indicator (red), Setting indicator (green) D2 Models: Operation indicator (red) 12 43 13 36 5 10 26.8 dia. *1 M12 x 1 Indicators*2 M30 x 1.5 Two clamping nuts Toothed washer *1. 6-dia. vinyl-insulated round cable, Standard length: 300 mm *2. D1 Models: Operation indicator (red), Setting indicator (green) D2 Models: Operation indicator (red) Mounting Hole Dimensions Dimension F (mm) M8 M12 M18 M30 8.5 +00.5 dia. 12.5 +00.5 dia. 18.5 +00.5 dia. 30.5 +00.5 dia. F 33 E2E Dimensions for Proximity Sensors with Sensor I/O Connectors Shielded Models Straight Connectors Unshielded Models Straight Connectors L1 L-shape Connectors L1 L-shape Connectors Dimensions with the XS2F/XS5F Connected Dimension Sensor diameter M8 DC M12* AC M18 M30 (Unit: mm) L1 L2 Approx. 75 Approx. 80 Approx. 85 Approx. 85 Approx. 90 Approx. 62 Approx. 67 Approx. 72 Approx. 72 Approx. 77 * The overall length of the Sensor is different between AC and DC Models for Sensors with diameters of M12. This will change the dimension when the I/ O Connector is connected. Dimensions with the XS3F Connected (Unit: mm) L2 L2 Dimension Sensor diameter M8 L1 L2 Approx. 65 Approx. 54 Accessories (Order Separately) Sensor I/O Connectors Refer to Introduction to Sensor I/O Connectors/Sensor Controllers for details. Mounting Brackets Protective Covers Sputter Protective Covers Refer to Y92@ for details. 34 Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron's exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron's sole obligation hereunder shall be, at Omron's election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron's analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer's application or use of the Product. At Buyer's request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer's application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user's programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron's test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron's Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron's representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. 2017.4 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2017 All Right Reserved.