Compact Type4 PLe SIL3 Light Curtain SF4B-C SERIES Conforming to Machine & EMC Directive Certified Conforming to OSHA/ANSI Introducing the Type 4 Compact Light Curtain Mounts flush on aluminum frames! 2013.06 panasonic.net/id/pidsx Certified by NRTL Certified Realizing compact design, light weight, and advanced functionality in one package: A new concept in compact light curtains The SF4B-C series comes in the previously unavailable size of 20 (W) x 27.4 (D) mm 0.787 (W) x 1.079 (D) in. These light curtains have been designed to be compact, lightweight, and easy to install, and they offer the extensive selection of safety features that you've come to expect from Panasonic Industrial Devices SUNX, including muting and blanking. Compact design Mounts flush on aluminum frames. 2 Lightweight High functionality Compact Light Curtain SF4B-C SERIES SF4B-C SERIES Compact design Featuring a compact design, so you can maximize the machinery opening. The SF4B-C series is designed to mount flush on an aluminum frame, allowing you to maximize the machinery opening. It can even be installed with zero dead zone. Side mounting Width Just 20 0.787 mm The light curtain does not protrude beyond the frame. in The light curtain's thin design allows protuberances to be minimized during mounting. *When using standard mounting brackets (optional). Issues when installing on the inside of the machinery opening Depth 27.4 1.079 Bracket mm Dead zone Light curtain mounting bracket Brackets in the corners of the aluminum frame result in dead zone. in A protective guard is required in the dead zone. Dead zone Buried mounting (side) Light curtain mounting bracket Bracket Rear mounting The light curtain mounts flush, even in embedded installations. The light curtain protrudes neither into the machinery opening nor outside the frame. There's no risk of workpieces bumping into the light curtain. The light curtain fits onto a 20 x 20 mm 0.787 x 0.787 in aluminum frame perfectly. It does not protrude from the frame. *When using standard mounting brackets (optional). *When using standard mounting brackets (optional). 3 Light weight Plastic and metal The SF4B-C series features a proprietary double structure that combines a plastic body that is designed to minimize weight with a metal inner frame that increases the device's toughness. Metal inner frame Strong Light Max. 1,623.4 mm 63.913 in Plastic seamless enclosure *The seamless enclosure has been cut away in this illustration. 45% lighter* for easy installation in high places and when mounting long models Thanks to its plastic body, the SF4B-C series is 45% lighter* than previous models with aluminum enclosures. This design helps reduce the overall weight of the system during transport and when shipping it overseas. *SF4B-H80 (V2) versus SF4B-H80CA-J05. Min. 263.4 mm 10.370 in Maximum detection width (protection height) of 1,623.4 mm 63.913 in Despite its compact, plastic body, the SF4B-C series features a metal inner frame that increases toughness and limits flex, allowing detection widths (protection heights) ranging from 263.4 mm to 1,623.4 mm 10.370 in to 63.913 in. High functionality Large multi-purpose indicator (SF4B-CA-J05 only) The SF4B-C series incorporates a large multi-purpose indicator (orange) positioned at workers' eye level. The indicator signals the presence of the light curtain, helping to prevent stoppages due to inadvertent interruption of its beams. The indicator can be used in a variety of applications, including as a muting indicator or work indicator. Exceptional visibility from the side The large multi-purpose indicator shines brightly through the plastic body to ensure exceptional visibility from the side. 4 SF4B-C SERIES High functionality The SFB-HC handycontroller (optional) offers easy access to settings for a range of functionality. Muting control function for individual beams: Limit the (SF4B-CA-J05 only) muting area During muting (line operating) Fixed blanking function: Choose active breams Line stopped The SFB-HC handy-controller (optional) allows you to perform muting control for certain beams only. Since you can specify the beams, there is no need to install a separate guard to prevent incursions. For example, if you use muting control from the lowermost beam to the 10th beam, the light curtain will detect any interruption of the 11th or higher beam as a person and stop the machinery. The SFB-HC handy-controller provides a fixed blanking function that prevents control output (OSSD) from turning off even if certain beams are interrupted. This capability is convenient in applications where an obstruction always interrupts certain beams. Additionally, a high level of safety is provided since control output (OSSD) is forcibly turned off in the event the obstruction moves outside the detection area. Using output and indicators based on the unstable light reception monitor to enable preventive maintenance By setting the auxiliary output change function to off or on when light reception becomes unstable, you can have the light curtain provide notification in the event of a reduction in the amount of light being received due to beam misalignment or dirt via auxiliary output (non-safety output) in addition to the light reception indicator. Auxiliary output Incident light intensity (Note 1) Incident light intensity indicator 130% 100% Floating blanking function: Disable unspecified beams Under stable light received condition: Green (Incident light intensity: 130% or greater) Under unstable light received condition: Orange (Incident light intensity: 100% to less than 130%) Set to off for unstable incident beam (Note 3) Set to on for unstable incident beam (Note 3) ON OFF OFF ON When light is interrupted (see Note 2): Off Notes: 1) An incident light intensity value of 100% is used as the threshold at which control output (OSSD1, OSSD2) changes from off to on. 2) Interruption of the light refers to the presence of a light-blocking obstruction in the detection area. 3) This setting is not available when using muting control for individual beams, fixed blanking, or floating blanking. The floating blanking function allows you to disable up to three unspecified beams. Control output (OSSD) will not turn off as long as the number of interrupted beams is less than the set number of beams. This capability is convenient when an obstruction must move inside the detection area during setup changes or when loading materials inside the light curtain's detection area. *The min. sensing object will change when the floating blanking function is used. High functionality Extensive array of other functions PNP / NPN polarity support Since a single model number can be switched between PNP and NPN input, fewer model numbers need to be registered. External device monitor function External devices (such as safety relays, etc.) can be directly connected to the handy-controller without any dedicated unit, simplifying installation, reducing costs, and helping avoid various issues and problems. Extraneous light check & avoid (ELCA) function The ELCA function reduces interference without the need for an interference prevention line. Beam alignment indicator A beam alignment indicator divides the light curtain's beams into four equal displays, allowing you to see at a glance where light is being received. 5 SF4B-C PRODUCT CONFIGURATION Pigtailed type (with muting function) Cable type (with 0.5 m 1.640 ft connector attached cable) (with 5 m 16.404 ft cable) 1 2 3 5 3 4 Cable 5 m 16.404 ft (discrete wire) Connector attached cable 0.5 m 1.640 ft ORDER GUIDE 1 2 Light curtains Hand protection type Arm / Foot protection type Min. sensing object o45 mm o1.772 in (40 mm 1.575 in beam pitch) Min. sensing object o25 mm o0.984 in (20 mm 0.787 in beam pitch) Type Operating range (Note 1) Appearance Beam channel No. 22.2 mm 0.874 in Protective height Beam pitch 20 mm 0.787 in 0.3 to 7 m 0.984 to 22.966 ft 22.2 mm 0.874 in 42.2 mm 1.661 in Beam pitch Protective 40 mm height 1.575 in Beam channel No. 0.3 to 7 m 0.984 to 22.966 ft 42.2 mm 1.661 in Model No. (Note 2) Number of beam channels Protective hight 1 Pigtailed type 2 Cable type SF4B-H12CA-J05 SF4B-H12C 12 263.4 mm 10.37 in SF4B-H16CA-J05 SF4B-H16C 16 343.4 mm 13.52 in SF4B-H20CA-J05 SF4B-H20C 20 423.4 mm 16.669 in SF4B-H24CA-J05 SF4B-H24C 24 503.4 mm 19.819 in SF4B-H28CA-J05 SF4B-H28C 28 583.4 mm 22.969 in SF4B-H32CA-J05 SF4B-H32C 32 663.4 mm 26.118 in SF4B-H36CA-J05 SF4B-H36C 36 743.4 mm 29.268 in SF4B-H40CA-J05 SF4B-H40C 40 823.4 mm 32.417 in SF4B-H48CA-J05 SF4B-H48C 48 983.4 mm 38.717 in SF4B-H56CA-J05 SF4B-H56C 56 1,143.4 mm 45.016 in SF4B-H64CA-J05 SF4B-H64C 64 1,303.4 mm 51.315 in SF4B-H72CA-J05 SF4B-H72C 72 1,463.4 mm 57.614 in 1,623.4 mm 63.913 in (with muting function) SF4B-H80CA-J05 SF4B-H80C 80 SF4B-A8CA-J05 SF4B-A8C 8 SF4B-A12CA-J05 SF4B-A12C 12 503.4 mm 19.819 in 343.4 mm SF4B-A16CA-J05 SF4B-A16C 16 663.4 mm 26.118 in SF4B-A20CA-J05 SF4B-A20C 20 823.4 mm 32.417 in SF4B-A24CA-J05 SF4B-A24C 24 983.4 mm 38.717 in SF4B-A28CA-J05 SF4B-A28C 28 1,143.4 mm 45.016 in SF4B-A32CA-J05 SF4B-A32C 32 1,303.4 mm 51.315 in SF4B-A36CA-J05 SF4B-A36C 36 1,463.4 mm 57.614 in SF4B-A40CA-J05 SF4B-A40C 40 1,623.4 mm 63.913 in Notes: 1) The operating range is the possible setting distance between the emitter and the receiver. Receiver cannot be placed in this range Actual operating range of the light curtain 0.3 m 0.984 ft 7 m 22.966 ft Setting range of the receiver Emitter Receiver Receiver 2) The model No. with "E" shown on the label affixed to the product is the emitter, "D" shown on the label is the receiver. 6 13.52 in SF4B-C ORDER GUIDE 3 Mounting brackets Mounting bracket is not supplied with the light curtain. Be sure to order it separately. Designation Appearance Standard mounting bracket Rear utility mounting bracket Side utility mounting bracket utility mounting bracket Intermediate support bracket for use with utility mounting bracket (Note 1) Intermediate supporting bracket for use with the standard mounting bracket (Note 1) Model No. Description MS-SF4BC-1 Allows the light curtain to be mounted on the rear or side of the target equipment. Designed for use with one M5 hexagon-socket head bolt. (4 pcs. per set for the emitter and receiver) MS-SF4BC-2 Allows the light curtain to be mounted on the rear of the target equipment. Allows beam adjustment. Designed for use with one M5 hex socket bolt. For space-saving mounting, use one M5 hex head bolt. (4 pcs. per set for the emitter and receiver) MS-SF4BC-3 Allows the light curtain to be mounted on the side of the target equipment. Allows beam adjustment. Designed for use with one M5 hex socket bolt. For space-saving mounting, use one M5 hex head bolt. (4 pcs. per set for the emitter and receiver) MS-SF4BC-4 Supports the middle of the light curtain when installing it with utility mounting brackets. Allows the light curtain to be mounted on the rear or side of the target equipment. Allows beam adjustment. Designed for use with one M3 hex socket bolt. (2 pcs. each per set for rear mounting and side mounting) MS-SF4BC-5 Supports the middle of the light curtain when installing it with standard mounting brackets. Allows the light curtain to be mounted on the rear or side of the target equipment. Designed for use with two M5 countersunk screws. (2 pcs. each per set for rear mounting and side mounting) Note 1: The numbers of sets required by SF4B-HC (A-J05) (40 or more beam axes) and SF4B-HC (A-J05) (20 or more beam axes) are as follows: SF4B-H40C (A-J05), SF4B-H48C (A-J05), SF4B-H56C (A-J05), SF4B-A20C (A-J05), SF4B-A24C (A-J05), SF4B-A28C (A-J05): 1 set SF4B-H64C (A-J05), SF4B-H72C (A-J05), SF4B-H80C (A-J05), SF4B-A32C (A-J05), SF4B-A36C (A-J05), SF4B-A40C (A-J05): 2 sets Standard mounting bracket and intermediate supporting bracket for use with the standard mounting bracket In case of rear mounting In case of side mounting Rear utility mounting bracket and intermediate support bracket for use with utility mounting bracket Space-saving mounting (Note 2) Standard mounting bracket MS-SF4BC-1 Standard mounting Side utility mounting bracket and intermediate support bracket for use with utility mounting bracket Space-saving mounting (Note 2) Side utility mounting bracket MS-SF4BC-3 Rear utility mounting bracket MS-SF4BC-2 Intermediate supporting bracket for use with the standard mounting bracket MS-SF4BC-5 Intermediate support bracket for use with utility mounting bracket MS-SF4BC-4 Intermediate support bracket for use with utility mounting bracket MS-SF4BC-4 Rear utility mounting bracket MS-SF4BC-2 Standard mounting bracket MS-SF4BC-1 Side utility mounting bracket MS-SF4BC-3 * MS-SF4BC-1 * MS-SF4BC-2 * MS-SF4BC-3 * MS-SF4BC-5 * MS-SF4BC-4 * MS-SF4BC-4 Four bracket set (two each R and L type) Eight M3 (length: 5 mm 0.197 in) hexagonsocket-head bolts and four 5M flat washers are attached. Two pcs. for rear mounting, two pcs. for side mounting Four bracket set (two each R and L type) Eight M3 (length: 5 mm 0.197 in) hexagonsocket-head bolts and four 5M flat washers are attached. Two pcs. M5 flat washers, two pcs. assembled M3 (length: 6 mm 0.236 in) hexagon-sockethead bolts for rear mounting, two pcs. attachments for side mounting Standard mounting Four bracket set (two each R and L type) Eight M3 (length: 5 mm 0.197 in) hexagonsocket-head bolts and four 5M flat washers are attached. Two pcs. M5 flat washers, two pcs. assembled M3 (length: 6 mm 0.236 in) hexagon-sockethead bolts for rear mounting, two pcs. attachments for side mounting Note 2: For space-saving mounting, use an M5 hexagon-socket-head bolt 7 SF4B-C ORDER GUIDE 4 5 Mating cables Type Description Length: 3 m 9.843 ft Net weight: 430 g approx. (2 cables) Cable with connector on one end for pigtailed type (with muting function) Two cables per set for emitter and receiver Length: 7m 22.966 ft Cable color: Gray (for emitter), Net weight: 1,000 g approx. (2 cables) Gray with black line (for receiver) Connector color: Gray (for emitter), Black (for receiver) Length: 10m 32.808 ft Net weight: 1,300 g approx. (2 cables) Min. bending radius: R6 mm R0.236 in With connector on one end SFB-CC7-MU SFB-CC10-MU For emitter 5 Model No. SFB-CC3-MU For receiver Mating cables With connectors on both ends 4 Appearance SFB-CCJ3E-MU Length: 3 m 9.843 ft Net weight: 190 g approx. (1 cable) SFB-CCJ10E-MU Length: 10m 32.808 ft Net weight: 660 g approx. (1 cable) SFB-CCJ3D-MU Length: 3 m 9.843 ft Net weight: 210 g approx. (1 cable) SFB-CCJ10D-MU Length: 10m 32.808 ft Net weight: 680 g approx. (1 cable) Cable with connectors on both ends for pigtailed type (with muting function) Cable color: Gray (for emitter), Gray with black line (for receiver) Connector color: Gray (for emitter), Black (for receiver) Min. bending radius: R6 mm R0.236 in Spare parts (Accessories for light curtain) Designation Model No. Test rod o25 SF4B-TR25 Description Min. sensing object for regular checking (o25 mm o0.984 in), with hand protection type (min. sensing object o25 mm o0.984 in) OPTIONS Control units Designation Appearance Slim type control unit Model No. Description SF-C13 Use a discrete wire cable to connect to the light curtain. Muting function can be used. Compatible with up to Control Category 4. When connecting pigtailed type (with muting function) SF4B-CA-J05, be sure to order a mating cable separately. * Bottom cap cable: SFB-CC-MU * Extension cable: SFB-CCJ-MU Handy-controller Designation Handycontroller Appearance Fix ed Floa bla ting nki Aux blan ng Lig iliary king ht con emoutput trol iss ion Pigtailed type (with muting function) Co de Mo Pr nitor ote Co ct py FU NC TIO N CA Model No. SFB-HC NC EL EN 8core TE R 8core FUNCTION 12-core 8-core * Includes 2 adapter cables Cable set for cable type connection 8-core 12-core CANCEL ENTER Adapter cable (Accessory) Adapter cable (Accessory) Extension cable Handy-controller SFC-WNC1 Cable type +V 0V Cable set Synchronization Synchronization + Control circuit Not used FUNCTION CANCEL Terminal block 8 ENTER Handy-controller SF4B-C OPTIONS Metal protection case On sale Designation Applicable beam channels Hand Arm / Foot protection type protection type Metal protection case * MS-SF4BCH- Model No. MS-SF4BCH-12 12 16 MS-SF4BCH-16 8 MS-SF4BCH-20 20 24 MS-SF4BCH-24 12 MS-SF4BCH-28 28 32 MS-SF4BCH-32 16 MS-SF4BCH-36 36 40 20 MS-SF4BCH-40 48 24 MS-SF4BCH-48 56 28 MS-SF4BCH-56 64 32 MS-SF4BCH-64 72 36 MS-SF4BCH-72 80 40 MS-SF4BCH-80 Note: The model Nos. given above denote a single unit. 2 units are required for use in mounting to the emitter / receiver. Others Large display unit for light curtain Designation Model No. Description Test rod o45 SF4B-TR45 Min. sensing object for regular checking (o45 mm o1.772 in), with arm / foot protection type (min. sensing object o45 mm o1.772 in) With the auxiliary output of the light curtain, the operation is easily observable from various directions. * SF-IND-2 M5 hexagonsockethead bolt (length: 10 mm 0.394 in or more) Purchase separately. Specifications Large display unit for light curtain SF-IND-2 * Supply voltage: 24 V DC 15 % * Current consumption: 12 mA or less * Indicators: Orange LED (8 pcs. used) [Light up when external contact is ON] * Ambient temperature: -10 to +55 C +14 to +131 F (No dew condensation or icing allowed) * Material: POM (Enclosure) Polycarbonate (Cover) Cold rolled carbon steel (SPCC) (Bracket) * Cable: 0.3 mm2 2-core cabtyre cable, 3 m 9.843 ft long * Weight: 70 g approx. (including bracket) * Cannot be attached together with a mounting bracket to the light curtain using a single bolt. Recommended safety relay Safety relay Panasonic Electric Works Co. Ltd. SF series Safety relay SFS3-L-DC24V (AG1S132) SFS4-L-DC24V (AG1S142) DIN terminal block SFS4-SFD (AG1S847) Note: Contact Panasonic Corporation for details on the recommended products. Item Type Model No. Order No. Contact arrangement Rated nominal switching capacity Min. switching capacity Coil rating Rated power consumption Operation time Release time Ambient temperature Applicable standards With LED indicator SFS3-L-DC24V SFS4-L-DC24V AG1S132 AG1S142 3a1b 4a2b 6 A / 250 V AC, 6 A / 30 V DC 1 mA / 5V DC 15 mA / 24 V DC 20.8 mA / 24 V DC 360 mW 500 mW 20 ms or less 20 ms or less -40 to +85 C -40 to +185 F (Humidity: 5 to 85 % RH) UL, C-UL, TUV 9 SF4B-C SPECIFICATIONS Item Model No. Light curtain individual specifications SF4B-HC (A-J05) Type Min. sensing object o25 mm o0.984 in (20 mm 0.787 in beam pitch) Pigtailed type SF4B-H12CA-J05 SF4B-H16CA-J05 SF4B-H20CA-J05 SF4B-H24CA-J05 SF4B-H28CA-J05 SF4B-H32CA-J05 SF4B-H36CA-J05 Cable type SF4B-H12C SF4B-H16C SF4B-H20C SF4B-H24C SF4B-H28C SF4B-H32C SF4B-H36C Number of beam channels Protective hight Pigtailed type Item Model No. Current consumption Cable type When large multi-purpose indicator turns OFF When large multi-purpose indicator lights up PFHD (Note 1) MTTFd (Note 1) Net weight Pigtailed type (Total of emitter and receiver) Cable type 12 263.4 mm 10.37 in 16 343.4 mm 13.52 in 24 503.4 mm 19.819 in 28 583.4 mm 22.969 in Emitter: 70 mA or less Receiver: 85 mA or less Emitter: 65 mA or less, Receiver: 75 mA or less Emitter: 80 mA or less Receiver: 95 mA or less 2.4 x 10-9 2.6 x 10-9 2.8 x 10-9 More than 100 years Approx. 480 g Approx. 550 g Approx. 630 g Approx. 820 g Approx. 890 g Approx. 970 g Emitter: 75 mA or less, Receiver: 85 mA or less 1.9 x 10-9 2.1 x 10-9 Approx. 330 g Approx. 670 g Approx. 400 g Approx. 740 g 32 663.4 mm 26.118 in Protective hight 40 823.4 mm 32.417 in 48 983.4 mm 38.717 in Pigtailed type Cable type Emitter: 80 mA or less When large multi-purpose Receiver: 100 mA or less indicator turns OFF When large multi-purpose Emitter: 90 mA or less indicator lights up Receiver: 110 mA or less PFHD (Note 1) 3.5 x 10-9 3.9 x 10-9 MTTFd (Note 1) Approx. 850 g Approx. 1,000 g Net weight Pigtailed type (Total of emitter and receiver) Cable type Approx. 1,200 g Approx. 1,300 g 56 1,143.4 mm 45.016 in 64 1,303.4 mm 51.315 in Emitter: 85 mA or less Receiver: 120 mA or less Emitter: 95 mA or less Receiver: 130 mA or less 4.4 x 10-9 4.8 x 10-9 More than 100 years Approx. 1,200 g Approx. 1,300 g Approx. 1,500 g Approx. 1,600 g 72 1,463.4 mm 57.614 in Emitter: 85 mA or less Receiver: 105 mA or less 3.0 x 10-9 3.3 x 10-9 Approx. 700 g Approx. 1,000 g 80 1,623.4 mm 63.913 in Emitter: 95 mA or less Receiver: 130 mA or less Emitter: 105 mA or less Receiver: 140 mA or less 5.3 x 10-9 5.7 x 10-9 Approx. 1,500 g Approx. 1,800 g Approx. 1,600 g Approx. 1,900 g Note: PFHd: Probability of dangerous failure per hour, MTTFd: Mean time to dangerous failure. Model No. SF4B-AC (A-J05) Item Type Min. sensing object o45 mm o1.772 in (40 mm 1.575 in beam pitch) Pigtailed type SF4B-A8CA-J05 SF4B-A12CA-J05 SF4B-A16CA-J05 SF4B-A20CA-J05 SF4B-A24CA-J05 SF4B-A28CA-J05 Cable type SF4B-A8C SF4B-A12C SF4B-A16C SF4B-A20C SF4B-A24C SF4B-A28C Number of beam channels Protective hight Pigtailed type Item Model No. Current consumption Cable type When large multi-purpose indicator turns OFF When large multi-purpose indicator lights up PFHD (Note 1) MTTFd (Note 1) Net weight Pigtailed type (Total of emitter and receiver) Cable type 8 343.4 mm 13.52 in 12 503.4 mm 19.819 in 16 663.4 mm 26.118 in 20 823.4 mm 32.417 in Protective hight Emitter: 65 mA or less Receiver: 75 mA or less Emitter: 70 mA or less Receiver: 85 mA or less Emitter: 70 mA or less Receiver: 80 mA or less 1.7 x 10-9 1.9 x 10-9 Emitter: 75 mA or less Receiver: 85 mA or less 2.2 x 10-9 2.4 x 10-9 More than 100 years Approx. 700 g Approx. 850 g Approx. 1,000 g Approx. 1,200 g Emitter: 80 mA or less Receiver: 95 mA or less 2.7 x 10-9 2.9 x 10-9 Approx. 400 g Approx. 740 g Approx. 550 g Approx. 890 g 32 1,303.4 mm 51.315 in 36 1,463.4 mm 57.614 in 40 1,623.4 mm 63.913 in Pigtailed type Current consumption Cable type Emitter: 75 mA or less When large multi-purpose Receiver: 95 mA or less indicator turns OFF When large multi-purpose Emitter: 85 mA or less indicator lights up Receiver: 105 mA or less PFHD (Note 1) 3.2 x 10-9 3.4 x 10-9 3.7 x 10-9 MTTFd (Note 1) More than 100 years Approx. 1,300 g Approx. 1,500 g Approx. 1,600 g Net weight Pigtailed type (Total of emitter and receiver) Cable type Approx. 1,600 g Approx. 1,800 g Approx. 1,900 g Note: PFHd: Probability of dangerous failure per hour, MTTFd: Mean time to dangerous failure. 10 28 1,143.4 mm 45.016 in Emitter: 60 mA or less Receiver: 70 mA or less Type Min. sensing object o45 mm o1.772 in (40 mm 1.575 in beam pitch) Pigtailed type SF4B-A32CA-J05 SF4B-A36CA-J05 SF4B-A40CA-J05 Cable type SF4B-A32C SF4B-A36C SF4B-A40C Number of beam channels 24 983.4 mm 38.717 in Approx. 1,000 g Approx. 1,300 g 36 743.4 mm 29.268 in Emitter: 75 mA or less Receiver: 95 mA or less Type Min. sensing object o25 mm o0.984 in (20 mm 0.787 in beam pitch) Pigtailed type SF4B-H40CA-J05 SF4B-H48CA-J05 SF4B-H56CA-J05 SF4B-H64CA-J05 SF4B-H72CA-J05 SF4B-H80CA-J05 Cable type SF4B-H40C SF4B-H48C SF4B-H56C SF4B-H64C SF4B-H72C SF4B-H80C Number of beam channels Current consumption 20 423.4 mm 16.669 in Approx. 1,200 g Approx. 1,500 g Approx. 780 g Approx. 1,100 g SF4B-C SPECIFICATIONS Light curtain common specifications Pigtailed type (with muting function) Min. sensing object Min. sensing object o25 mm o0.984 in o45 mm o1.772 in (20 mm 0.787 in beam pitch) (40mm 1.575 in beam pitch) Model No. SF4B-HCA-J05 SF4B-ACA-J05 Type Applicable standards Item International standard IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL3) Japan Europe (EU) (Note 2) North America (Note 3) South Korea (S-Mark) Operating range (Note 4) Beam pitch Min. sensing object (Note 5) Effective aperture angle Supply voltage Control outputs (OSSD 1, OSSD 2) Operation mode Protection circuit Response time Auxiliary output (Non-safety output) Cable type Min. sensing object Min. sensing object o25 mm o0.984 in o45 mm o1.772 in (20 mm 0.787 in beam pitch) (40mm 1.575 in beam pitch) SF4B-HC SF4B-AC JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508 (SIL3) EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL3), EN 55011, EN 50178, EN 61000-6-2 ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14, OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06 S1-G-35-2005, S2-W-11-2003 0.3 to 7 m 0.984 to 22.966 ft 20 mm 0.787 in 40 mm 1.575 in 20 mm 0.787 in 40 mm 1.575 in o25 mm o0.984 in opaque object o45 mm o1.772 in opaque object o25 mm o0.984 in opaque object o45 mm o1.772 in opaque object 2.5 or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / UL 61496-2)] 24 V DC 10% Ripple P-P 10% or less PNP open-collector transistor / NPN open-collector transistor (switching method) <For NPN output> <For PNP output> * Maximum source current: 200 mA * Maximum sink current: 200 mA * Applied voltage: Same as supply voltage (between the control output * Applied voltage: Same as supply voltage (between the control output and +V) and 0V) * Residual voltage: 2.5 V or less * Residual voltage: 2.5 V or less (source current 200 mA, when using 20 m 65.617 ft length cable) (sink current 200 mA, when using 20 m 65.617 ft length cable) * Leakage current: 0.1 mA or less (Including power supply OFF * Leakage current: 0.1 mA or less (Including power supply OFF condition) condition) * Maximum load capacity: 0.22 F (No load to maximum output current) * Maximum load capacity: 0.22 F (No load to maximum output current) * Load wiring resistance: 3 or less * Load wiring resistance: 3 or less ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the light curtain or the synchronization signal) (Note 6, 7) Incorporated OFF response: 14 ms or less, ON response: 80 to 90 ms PNP open-collector transistor / NPN open-collector transistor (switching method) <For PNP output> * Maximum source current: 60 mA * Applied voltage: Same as supply voltage (between the auxiliary output and +V) * Residual voltage: 2.5 V or less (source current 60 mA, when using 20 m 65.617 ft length cable) <For NPN output> * Maximum sink current: 60 mA * Applied voltage: Same as supply voltage (between the auxiliary output and 0 V) * Residual voltage: 2.5 V or less (sink current 60 mA, when using 20 m 65.617 ft length cable) OFF when control outputs are ON, ON when control outputs are OFF (Factory setting, operating mode can be changed using the SFB-HC handy-controller). Incorporated NPN open-collector transistor * Maximum sink current: 100 mA * Applied voltage: Same as supply voltage (between the Muting auxiliary output muting auxiliary output and 0 V) * Residual voltage: 2.5 V or less (sink current 100 mA, when using 20 m 65.617 ft length cable) Operation mode When muting auxiliary output: ON Protection circuit Incorporated ELCA function Incorporated (reducing mutual interference automatically) Emission halt function Incorporated Interlock function Incorporated [Manual reset / Auto reset (Note 8)] External device monitoring function Incorporated Override function Incorporated Muting function Incorporated Large multi-purpose indicator function Incorporated Muting setting changing, override setting changing, fixed Fixed blanking, floating blanking, light emitting amount control, blanking, floating blanking, light emitting amount control, Optional functions auxiliary output switching, protecting, interlock setting auxiliary output switching, protecting, interlock setting changing, external relay monitor setting changing changing, external relay monitor setting changing Pollution degree 3 Operating altitude 2,000 m 6,561.68 ft or less (Note 10) Degree of protection IP65 (IEC) Ambient temperature -10 to +55 C +14 to +131 F (No dew condensation or icing allowed), Storage: -25 to +60 C -3 to +140F Ambient humidity 30 to 85 % RH, Storage: 30 to 85 % RH Ambient illuminance Incandescent light: 3,500 x or less at the light-receiving face Dielectric strength voltage / 1,000 V AC for one min. between all supply terminals connected together and enclosure / 20 M or more, with 500 V DC Insulation resistance megger between all supply terminals connected together and enclosure 10 to 55 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each / 300 m/s2 acceleration Vibration resistance / (30 G approx.) in X, Y and Z directions for three times each Shock resistance Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 C +68 F. 2) Regarding EU Machinery Directive, a Notified Body, TUV SUD, has certified with the type examination certificate. 3) The product has been safety-certified in accordance with UL, ANSI, CSA, and other standards by TUV SUD, a nationally recognized safety laboratory (NRTL) that has been approved by the Occupational Safety and Health Administration (OSHA) as defined by 29 CFR 1910.7 4) The operating range is the possible setting distance between the emitter and the receiver. 5) In case the blanking function is valid, the operation mode is changed. For details, refer to "Safety distance" (p.22) 6) During muting, control output will not turn off even if the beams are interrupted. 7) When the blanking function is enabled, the operating mode will change. 8) The manual reset and automatic reset are possible to be switched depending on the wiring status. 9) In case of using optional function, the handy-controller SFB-HC is required. 10) Do not use or store the device in an environment where the air pressure is higher than the atmospheric pressure at an altitude of 0 meters. Environmental resistance Operation mode Protection circuit * * * * * * * * 11 SF4B-C SPECIFICATIONS Light curtain common specifications Pigtailed type (with muting function) Min. sensing object Min. sensing object Type o25 mm o0.984 in o45 mm o1.772 in (20 mm 0.787 in beam pitch) (40 mm 1.575 in beam pitch) Model No. SF4B-HCA-J05 SF4B-ACA-J05 Item Emitting element Material Cable Cable extension Infrared LED (Peak emission wavelength: 850nm) Enclosure: Polycarbonate 0.15 mm2 (power supply line: 0.2 mm2) 12-core heat0.15 mm2 (power supply line: 0.2 mm2) 8-core heatresistant PVC cable with connector, 0.5 m 1.640 ft long resistant PVC cable, 5 m 16.404 ft long Extension up to total 50 m 164.042 ft is possible for Extension up to total 50 m 164.042 ft is possible for both emitter and receiver optional mating cables 0.2 mm2 or more, cable (Note 11) SF4B-TR25 (Test rod): 1 pc. Accessories Cable type Min. sensing object Min. sensing object o25 mm o0.984 in o45 mm o1.772 in (20 mm 0.787 in beam pitch) (40 mm 1.575 in beam pitch) SF4B-HC SF4B-AC SF4B-TR25 (Test rod): 1 pc. Notes: 11) When the synchronization+ wire (orange) and synchronization- wire (orange / black) is extended with a cable other than exclusive cable, use a 0.2 mm2 or more shielded twisted pair cable. Control units Model No. Connectable light curtains Applicable standards Control category Supply voltage Current consumption Fuse (rating) Enabling path Utilization category Rated operation voltage (Ue) / Rated operation current (le) Contact resistance Contact protection fuse rating Pick-up delay (Auto reset / Manual reset) Response time Auxiliary output Rated operation voltage / current Contact protection fuse rating Semiconductor auxiliary output (AUX) Output operation Excess voltage category Polarity selection function Environmental resistance Pollution degree Protection Ambient temperature Ambient humidity Vibration resistance Enclosure material Weight SF-C13 Light curtains manufactured by Panasonic Industrial Devices SUNX EN 61496-1 (Type 4), EN 55011, EN ISO 13849-1 (Category 4, PLe), IEC 61496-1 (Type 4), ISO 13849-1 (Category 4, PLe), JIS B 9704-1 (Type 4), JIS B 9705-1 (Type 4), ANSI/UL 61496-1 (Type 4), UL 1998 (Class 2) ISO 13849-1 (EN ISO 13849-1, JIS B 9705-1) compliance up to Category 4, PLe standards 24 V DC 10 % Ripple P-P 10 % or less 100 mA or less (excluding light curtain) Built-in electronic fuse, Triggering current: 0.5 A or more, Reset after power down NO contact x 3 (13-14, 23-24, 33-34) AC-15, DC-13 (IEC 60947-5-1) 30 V DC / 4 A, 230 V AC / 4 A, resistive load (For inductive load, during contact protection) Min. applicable load: 10 mA (at 24 V DC) (Note 2) 100 m or less (initial value) 4 A (slow blow) 80 ms or less / 90 ms or less 10 ms or less Safety relay contact (NC contact) x 1 (41-42) (Related to enabling path) 24 V DC / 2 A, Min. applicable load: 10 mA (at 24 V DC) 2 A (slow blow) PNP opencollector transistor * Maximum source current: 60 mA ON when the light curtain is interrupted II Incorporated (Cable connection allows selection of plus / minus ground) Minus ground: Correspond to PNP output light curtain Plus ground: Correspond to NPN output light curtain 2 Enclosure: IP40, Terminal: IP20 -10 to +55 C +14 to +131 F (No dew condensation or icing allowed), Storage: -25 to +70 C -13 to +158 F 30 to 85% RH, Storage: 30 to 90% RH Resistance / malfunction 10 to 55 Hz frequency, 0.35 mm 0.014 in amplitude in X, Y, and Z directions for twenty times each ABS Net weight: 200 g approx. Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 C +68 F. 2) If several SF-C13units are being used in line together, leave a space of 5 mm 0.197 in or more between each unit. If the units are touching each other, reduce the rated operating current for safety output in accordance with the ambient operating temperature as shown in the graphs at right. 3) Refer to our website for details of specifications. Dilating when SF-C13 units are mounted close together 6 Rated operation current (A) Item 5 4 3 2 1 0 32 12 35 40 45 50 55 95 104 113 122 131 Ambient temperature (C F) SF4B-C SPECIFICATIONS Handy-controller Model No. Item Supply voltage Current consumption Communication method Digital display Function indicator Functions Ambient temperature Ambient humidity Voltage withstandability Insulation resistance Cable Weight Accessories SFB-HC 24 V DC 10 % Ripple P-P10 % or less (common to light curtain power supply) 65 mA or less RS-485 two-way communications (Specific procedure) 4-digit red LED display x 2 (Selected beam channels, setting contents etc. are displayed.) Green LED x 9 (set function is displayed.) Fixed blanking (Factory setting: Disabled) / Floating blanking (Factory setting: Disabled) / Auxiliary output change (Factory setting: Negative Logic of OSSD) / Light emitting amount control (Factory setting: Disabled) / Muting setting change [Factory setting: All beam channels enabled, A = B, Setting of the muting lamp diagnosis function enabled (Ver. 2 or later), Muting sensor output operation setting N.O. / N.O. (Ver. 2.1 or later)] / Interlock setting change (Factory setting: start / restart) / External device monitoring setting change (Factory setting: Enabled, 300 ms) / Override setting changing function 60 sec. (Ver. 2.1 or later) / Setting detail monitoring / / Protecting (Factory setting: Disabled) (Factory password setting: 0000) / Initialization / Copy -10 to +55 C +14 to +131 F (No dew condensation or icing allowed), Storage: -25 to +70 C -13 to +158 F 30 to 85 % RH, Storage: 30 to 85 % RH 1,000 V AC for one min. between all supply terminals connected together and enclosure 20 M , or more, with 500 V DC megger between all supply terminals connected together and enclosure 8-core shielded cable, 0.5 m 1.640 ft long, with a connector at the end (2 cables) Net weight: 200 g approx. Adapter cable: 2 cables Note: Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 C +68 F. 13 SF4B-C I/O CIRCUIT AND WIRING DIAGRAMS SF4B-CA-J05 Pigtailed type (with muting function) I/O circuit diagram <In case of using I/O circuit for PNP output> <In case of using I/O circuit for NPN output> Terminal No. of pigtailed type Emitter Terminal No. of pigtailed type Emitter Color code of mating cable Color code of mating cable (Brown) +V (Brown) +V (Shield) Output polarity setting wire (Yellow) Override input 0.22 F 470 0.22 F 470 (Pink) Emission halt input / *S1 Reset input 0.22 F 470 (Pale purple) Interlock setting input (Red) Muting auxiliary output *S1 Load Load (Yellow-green / Black) Auxiliary output *S1 + - (Yellow-green / Black) Auxiliary output 24 V DC 10 % (Gray / Black) Large multi-purpose *S1 indicator input (Emitter side) (Gray / Black) Large multi-purpose indicator input (Emitter side) Sensor circuit Sensor circuit (Red) Muting auxiliary output (Gray) NC 470 (Pale purple) Interlock setting input (Gray) NC 0.22 F 470 (Pink) Emission halt input / *S1 Reset input (Shield) Output polarity setting wire 0.22 F 470 (Yellow) Override input (Blue) 0 V (Orange) Synchronization+ (Orange) Synchronization+ - 24 V DC 10 % (Orange / Black) SynchronizationInternal circuit Users' circuit Receiver Users' circuit Receiver 1 k 0.047 F 1 k (Orange / Black) Synchronization- (Orange) Synchronization+ (Orange) Synchronization+ (Brown) +V (Brown) +V (Sky-blue / White) Muting input A (Shield) Output polarity setting wire (Sky-blue / Black) Muting input B K1 *S1 (Yellow-green) External device monitor input K2 K1 K2 470 Sensor circuit (Black) Control output 1 (OSSD 1) *S1 *S1 (Gray / Black) Large multi-purpose indicator input (Receiver side) Sensor circuit 0.047 F (Orange / Black) Synchronization- (Gray) NC (White) Control output 2 (OSSD 2) (Gray / Black) Large multi-purpose indicator input (Receiver side) *S1 (Black) Control output 1 (OSSD 1) (Gray) NC (White) Control output 2 (OSSD 2) K1 (Shield) Output polarity setting wire K2 Internal circuit K1, K2: External device (Forced guided relay or magnetic contactor) Users' circuit 470 0.047 F 1 k (Sky-blue / White) Muting input A 0.047 F 1 k (Sky-blue / Black) Muting input B *S1 Switch S1 * Emission halt input / Reset input For manual reset Vs to Vs - 2.5 V (sink current 5 mA or less): Emission halt (Note), Open: Emission For automatic reset Vs to Vs - 2.5 V (sink current 5 mA or less): Emission (Note), Open: Emission halt * Interlock setting input, Override input, Muting input A / B, External device monitor input Vs to Vs - 2.5 V (sink current 5 mA or less): Valid (Note), Open: Invalid * Large multi-purpose indicator input 0 to +1.5 V (source current: 5 mA or less): Lights up, Open: Turn OFF Note: Vs is the applying supply voltage. Internal circuit K1 K2 (Yellow-green) External device monitor input 0.22 F (Blue) 0 V 14 + *S1 (Blue) 0 V (Orange / Black) Synchronization- 0.22 F *S1 *S1 0.22 F Load Internal circuit Load *S1 *S1 (Blue) 0 V K1, K2: External device (Forced guided relay or magnetic contactor) Users' circuit *S1 Switch S1 * Emission halt input / Reset input For manual reset 0 to +1.5 V (source current 5 mA or less): Emission halt, Open: Emission For automatic reset 0 to +1.5 V (source current 5 mA or less): Emission, Open: Emission halt * Interlock setting input, Override input, Muting input A / B, External device monitor input 0 to +1.5 V (source current: 5 mA or less): Valid, Open: Invalid * Large multi-purpose indicator input 0 to +1.5 V (source current: 5 mA or less): Lights up, Open: Turn OFF SF4B-C I/O CIRCUIT AND WIRING DIAGRAMS SF4B-CA-J05 Pigtailed type (with muting function) Connection example Muting control components: Interlock function "disabled (automatic reset)", external device monitoring function "enabled" <In case of using I/O circuit for PNP output> Color code of mating cable The diagram at left shows the configuration when using PNP output, interlock function "disabled (automatic reset)" and external device monitoring function "enabled". (Gray) NC (Gray / Black) Large multi-purpose indicator input (Emitter side) Gray cable (Pale purple) Interlock setting input (Brown) +V (Pink) Emission halt input / Reset input Emitter Receiver (Red) Muting auxiliary output *S1 Load *S1 + (Yellow) Override input (Yellow-green / Black) Auxiliary output (Shield) Output polarity setting wire - Load 24 V DC 20 % In case of setting the interlock function to "enabled (manual reset)" **When the interlock function is set to "Enable (manual reset)," the override function cannot be used. Emitter (Blue) 0 V (Orange) Synchronization+ *S1 (Orange / Black) Synchronization- +24 V DC (Orange / Black) Synchronization(Pink) Emission halt input / Reset input (Orange) Synchronization+ Gray cable (with black line) K1 K2 (Yellow-green) External device monitor input (Brown) +V *S1 *S1 (Sky-blue / White) Muting input A (Pale purple) Interlock setting input In case of setting the external device monitoring function to "disabled" (Sky-blue / Black) Muting input B (Black) Control output 1 (OSSD 1) (White) Control output 2 (OSSD 2) (Shield) Output polarity setting wire Emitter K1 K2 (Blue) 0 V (Gray / Black) Large multi-purpose indicator input (Receiver side) (Yellow-green / Black) Auxiliary output (Gray) NC K1, K2: External device (Forced guided relay or magnetic contactor) *S1 Receiver Switch S1 * Emission halt input / Reset input For automatic reset Vs to Vs - 2.5 V (sink current 5 mA or less): Emission (Note) Open: Emission halt For manual reset Vs to Vs - 2.5 V (sink current 5 mA or less): Emission halt (Note) Open: Emission * Muting input A / B, Override input Vs to Vs - 2.5 V (sink current 5 mA or less): Valid (Note), Open: Invalid (Yellow-green) External device monitor input Note: Vs is the applying supply voltage. <In case of using I/O circuit for NPN output> Color code of mating cable Emitter Receiver Gray cable (Gray) NC (Gray / Black) Large multi-purpose indicator input (Emitter side) (Pale purple) Interlock setting input (Brown) +V (Yellow-green / Black) Auxiliary output Load (Shield) Output polarity setting wire (Red) Muting auxiliary output Load (Yellow) Override input (Pink) Emission halt input / Reset input *S1 (Blue) 0 V (Orange) Synchronization+ (Orange / Black) Synchronization(Orange / Black) Synchronization(Orange) Synchronization+ Gray cable (with black line) (Yellow-green) External device monitor input (Brown) +V (Black) Control output 1 (OSSD 1) K1 (White) Control output 2 (OSSD 2) K2 (Shield) Output polarity setting wire (Sky-blue / White) Muting input A (Sky-blue / Black) Muting input B *S1 The diagram at left shows the configuration when using NPN output, interlock function "disabled (automatic reset)" and external device monitoring function "enabled". + *S1 - 24 V DC 20 % In case of setting the interlock function to "enabled (manual reset)" **When the interlock function is set to "Enable (manual reset)," the override function cannot be used. Emitter (Pale purple) Interlock setting input (Pink) Emission halt input / Reset input *S1 K1 K2 0V In case of setting the external device monitoring function to "disabled" Emitter *S1 (Blue) 0 V (Gray / Black) Large multi-purpose indicator input (Receiver side) (Gray) NC *S1 (Yellow-green / Black) Auxiliary output K1, K2: External device (Forced guided relay or magnetic contactor) Switch S1 * Emission halt input / Reset input For automatic reset 0 to +1.5 V (source current 5 mA or less): Emission, Open: Emission halt For manual reset 0 to +1.5 V (source current 5 mA or less): Emission halt, Open: Emission * Muting input A / B, Override input 0 to + 1.5 V (source current: 5mA or less): Valid, Open: Invalid Receiver (Yellow-green) External device monitor input 15 SF4B-C I/O CIRCUIT AND WIRING DIAGRAMS SF4B-C Cable type I/O circuit diagram <In case of using I/O circuit for PNP output> Emitter Color code of mating cable 470 0.22 F 470 Sensor circuit 0.22 F (Brown) +V (Pale purple) Interlock setting input (Shield) Output polarity setting wire Load (Pink) Emission halt input / Reset input *S1 *S1 + (Yellow-green / Black) Auxiliary output - 24 V DC 10 % Load (Shield) Output polarity setting wire (Blue) 0 V Internal circuit Receiver Color code of mating cable (Brown) +V Sensor circuit Emitter <In case of using I/O circuit for NPN output> (Yellow-green / Black) Auxiliary output - 0.22 F 470 0.22 F 470 (Orange) Synchronization+ (Orange / Black) Synchronization- Users' circuit Internal circuit Receiver (Orange / Black) Synchronization(Orange) Synchronization+ (Brown) +V (Brown) +V (Shield) Output polarity setting wire K1 K2 K1 (Black) Control output 1 (OSSD 1) Sensor circuit (Black) Control output 1 (OSSD 1) Sensor circuit Users' circuit (Orange) Synchronization+ 470 *S1 (Blue) 0 V (Orange / Black) Synchronization- (Yellow-green) External device monitor input 0.22 F (Pink) Emission halt input / Reset input 24 V DC 10 % *S1 (Pale purple) Interlock setting input (Orange) Synchronization+ (Orange / Black) Synchronization- + (White) Control output 2 (OSSD 2) K2 (White) Control output 2 (OSSD 2) K1 (Shield) Output polarity setting wire K2 (Blue) 0 V Internal circuit K1, K2: External device (Forced guided relay or magnetic contactor) Users' circuit *S1 Switch S1 * Emission halt input / Reset input For manual reset Vs to Vs - 2.5 V (sink current 5 mA or less): Emission halt (Note), Open: Emission For automatic reset Vs to Vs - 2.5 V (sink current 5 mA or less): Emission (Note), Open: Emission halt * Interlock setting input Vs to Vs - 2.5 V (sink current 5 mA or less): Valid (Note), Open: Invalid Note: Vs is the applying supply voltage. 16 (Yellow-green) External device monitor input K1 K2 0.22 F 470 Internal circuit (Blue) 0 V K1, K2: External device (Forced guided relay or magnetic contactor) Users' circuit *S1 Switch S1 * Emission halt input / Reset input For manual reset 0 to +1.5 V (source current 5 mA or less): Emission halt, Open: Emission For automatic reset 0 to +1.5 V (source current 5 mA or less): Emission, Open: Emission halt * Interlock setting input 0 to +1.5 V (source current: 5 mA or less): Valid, Open: Invalid SF4B-C I/O CIRCUIT AND WIRING DIAGRAMS SF4B-C Cable type Connection example Interlock function "enabled (manual reset)", external device monitoring function "enabled" <In case of using I/O circuit for PNP output> The diagram at left shows the configuration when using PNP output, interlock function "enabled (manual reset)" and external device monitoring function "enabled". Emitter Receiver Color code of mating cable (Brown) +V Gray cable *S1 (Pale purple) Interlock setting input (Pink) Emission halt input / Reset input (Yellow-green / Black) Auxiliary output (Shield) Output polarity setting wire + - Load 24 V DC 10 % In case of setting the interlock function to "disabled (automatic reset)" Emitter +24 V DC (Blue) 0 V *S1 (Orange) Synchronization+ (Orange / Black) Synchronization(Orange / Black) Synchronization- (Pink) Emission halt input / Reset input (Orange) Synchronization+ Gray cable (with black line) (Pale purple) Interlock setting input (Yellow-green) External device monitor input K1 K2 Open (Brown) +V (Black) Control output 1 (OSSD 1) K1 (White) Control output 2 (OSSD 2) In case of setting the external device monitoring function to "disabled" K2 (Shield) Output polarity setting wire (Blue) 0 V Emitter K1, K2: External device (Forced guided relay or magnetic contactor) *S1 (Yellow-green / Black) Auxiliary output Switch S1 * Emission halt input / Reset input For manual reset Vs to Vs - 2.5 V (sink current 5 mA or less): Emission halt (Note), Open: Emission For automatic reset Vs to Vs - 2.5 V (sink current 5 mA or less): Emission (Note), Open: Emission halt * Interlock setting input Vs to Vs - 2.5 V (sink current 5 mA or less): Valid (Note), Open: Invalid Receiver (Yellow-green) External device monitor input Note: Vs is the applying supply voltage. <In case of using I/O circuit for NPN output> The diagram at left shows the configuration when using NPN output, interlock function "enabled (manual reset)" and external device monitoring function "enabled". Emitter Receiver Color code of mating cable Gray cable (Brown) +V (Yellow-green / Black) Auxiliary output (Shield) Output polarity setting wire In case of setting the interlock function to "disabled (automatic reset)" Emitter Load (Pink) Emission halt input / Reset input + *S1 (Pale purple) Interlock setting input - 24 V DC 10 % (Blue) 0 V (Orange) Synchronization+ (Pale purple) Interlock setting input (Orange / Black) Synchronization- (Pink) Emission halt input / Reset input (Orange / Black) Synchronization- *S1 (Orange) Synchronization+ Gray cable (with black line) (Yellow-green) External device monitor input K1 K2 0V (Brown) +V (Black) Control output 1 (OSSD 1) (White) Control output 2 (OSSD 2) (Shield) Output polarity setting wire Open K1 K2 (Blue) 0 V In case of setting the external device monitoring function to "disabled" Emitter K1, K2: External device (Forced guided relay or magnetic contactor) *S1 Switch S1 * Emission halt input / Reset input For manual reset 0 to +1.5 V (source current 5 mA or less): Emission halt, Open: Emission For automatic reset 0 to +1.5 V (source current 5 mA or less): Emission, Open: Emission halt * Interlock setting input 0 to +1.5 V (source current: 5 mA or less): Valid, Open: Invalid (Yellow-green / Black) Auxiliary output Receiver (Yellow-green) External device monitor input 17 SF4B-C I/O CIRCUIT AND WIRING DIAGRAMS SF-C13 SF4B-C wiring diagram (Control Category 4) For PNP output (minus ground) **Connect the light curtain control outputs OSSD 1 and OSSD 2 to S1 and S2 respectively. Emitter Emitter Receiver Synchronization+ (Orange) Synchronization(Orange / Black) +V (Brown) +24 V DC Load Synchronization+ (Orange) Synchronization(Orange / Black) Output polarity Emission Auxiliary output Interlock setting setting wire halt input / (Yellow-green input (Pale purple) (Shield) Reset input / Black) Open (Pink) +V (Brown) 0 V (Blue) Load Output polarity setting wire (Shield) 0 V (Blue) Cable color: Gray with black line Cable color: Gray +V (Brown) +24 V DC Emission halt input / Auxiliary output Interlock setting Reset input (Yellow-green input (Pale purple) / Black) Open +V (Brown) (Pink) 0 V (Blue) Receiver Cable color: Gray with black line Cable color: Gray Output polarity setting wire (Shield) For NPN output (plus ground) **Connect the light curtain control outputs OSSD 1 and OSSD 2 to S4 and S2 respectively and ground the + side. 0 V (Blue) External device monitor input (Yellow-green) External device monitor input (Yellow-green) OSSD 2 (White) OSSD 1 (Black) OSSD 1 (Black) OSSD 2 (White) L1 L1 RESET (Note 1, 2) A1 S1 S2 S3 (Note 1) S4 X1 X2 FUSE1 X3 13 23 F (Note 1) FUSE2 33 41 A1 F.G. S1 S2 S3 S4 X1 X2 F K1 Ui A2 0V 14 24 F.G. KA N KA, KB: External device (Forced guided relay or magnetic contactor) 34 42 L1L2L3 KB OUT KB KA M 3 Notes: 1) The above diagram is when using manual reset. If automatic reset is used, disconnect the lead from X2 and connect it to X3. In this case, a reset (RESET) button is not needed. 2) Use a momentary-type switch as the reset (RESET) button. Terminal arrangement diagram A1 A2 S1 S2 S3 S4 AUX X1 X2 X3 13 14 23 24 33 34 41 42 Terminal Description A1 +24 V DC A2 0V S1 to S4 AUX Light curtain control output (OSSD) input terminal Semiconductor auxiliary output X1 Reset output terminal X2 Reset input terminal (Manual) X3 Reset input terminal (Automatic) 13-14, 23-24, 33-34 Enabling path (NO contact x 3) 41-42 Auxiliary output (NC contact x 1) When wiring connections to the light curtain, you are responsible for providing a terminal block. 18 33 41 RESET (Note 1, 2) K2 FAULT AUX FUSE2 SF-C13 control circuit K2 INTER_LOCK FUSE1 X3 13 23 K1 Ui SF-C13 control circuit OUT Output polarity setting wire (Shield) A2 INTER_LOCK AUX 0V KA, KB: External device (Forced guided relay or magnetic contactor) FAULT 14 24 KA N 34 42 L1L2L3 KB KB KA M 3 Notes: 1) The above diagram is when using manual reset. If automatic reset is used, disconnect the lead from X2 and connect it to X3. In this case, a reset (RESET) button is not needed. 2) Use a momentary-type switch as the reset (RESET) button. SF4B-C Refer to the instruction manual for details. The instruction manual can be download from our website. PRECAUTIONS FOR PROPER USE Wiring Emission halt function Refer to the applicable regulations for the region where this device is to be used when setting up the device. In addition, make sure that all necessary measures are taken to prevent possible dangerous operating errors resulting from earth faults. **Make sure to carry out the wiring in the power supply off condition. **Verify that the supply voltage variation is within the rating. **If power is supplied from a commercial switching regulator, ensure that the frame ground (F.G.) terminal of the power supply is connected to an actual ground. **In case noise generating equipment (switching regulator, inverter motor, etc.) is used in the vicinity of this sensor, connect the frame ground (F.G.) terminal of the equipment to an actual ground. **Do not run the wires together with high-voltage lines or power lines or put them in the same raceway. This can cause malfunction due to induction. Interlock function **The selection of manual reset / automatic reset is available by applying the interlock input (pale purple) wiring. The interlock becomes available by selecting manual reset. Interlock setting input wire (pale purple) Interlock function When selecting PNP output: Connected to +V When selecting NPN output: Connected to 0 V Manual reset Open Automatic reset In case of using the interlock function, be sure there exists no operator inside of the dangerous area. It causes death or serious injury without the confirmation. Manual reset **The control outputs (OSSD 1, OSSD 2) are not turned ON automatically even though this device is received the light. When this device is reset in light received state [open the emission halt input / reset input short-circuit the device to 0 V or +V open], the control outputs (OSSD 1, OSSD 2) are turned ON. The reset switch shall be placed in area where all over the dangerous zone shall be comprehend and out side of the dangerous zone. Automatic reset **The control output (OSSD 1, OSSD 2) is turned ON automatically when this device receives the light. Emitter +24 V DC (or 0 V) **This function stops the emission process of the emitter. You can select whether emission is on or halted by means of the connection status for the emission halt input / reset input wire (pink). Interlock function Emission halt input / Reset input wire (pink) Open When selecting PNP output: Manual Connected to +V reset When selecting NPN output: Connected to 0 V Open When selecting PNP output: Automatic Connected to +V reset When selecting NPN output: Connected to 0 V Emission Control output status halt (OSSD 1, OSSD 2) Invalid ON Valid OFF Valid OFF Invalid ON **During emission halt, the control outputs (OSSD 1, OSSD 2) become OFF status. **By using this function, malfunction due to extraneous noise or abnormality in the control outputs (OSSD 1, OSSD 2) and the auxiliary output can be determined even from the machinery side. **Normal operation is restored when the emission halt input / reset input wire (pink) is connected to 0 V or +V (for manual reset: open). Do not use the emission halt function for the purpose of stopping the machine in which the SF4B-C series is installed. Failure to do so could result in death or serious injury. External device monitoring function **This is the function for checking whether the external safety relay connected to the control outputs (OSSD 1, OSSD 2) perform normally in accordance with the control outputs (OSSD 1, OSSD 2) or not. Monitor the contacting point "b" of the external safety relay, and if any abnormality such as deposit of the contacting point, etc. is detected, change the status of the light curtain into lockout one, and turn OFF the control outputs (OSSD 1, OSSD 2). In case of setting the external device monitoring function to enabled **Connect the external device monitoring input (yellowgreen) to the external safety relay connected the control outputs (OSSD 1, OSSD 2). In case of not using the external device monitoring function **Connect the external device monitoring input (yellowgreen) to the auxiliary output (yellow-green / black). At this time, set the auxiliary output as [negative logic of control outputs (OSSD 1, OSSD 2)] (factory setting). **The auxiliary output cannot be connected to external devices. Emitter Receiver Emission halt input / Reset input (Pink) Interlock setting input (Pale purple) Open In case that this light curtain is used under automatic reset mode, set the system not to be auto reset by the safety relay unit, etc. (conforming to EN 60204-1) **It is possible to change the conditions for interlocking by using the handy-controller SFB-HC (optional). Refer to instruction manual enclosed with this product for details. Auxiliary output (Yellow-green / Black) External device monitor input (Yellow-green) **It is also possible to set the external device monitoring function into invalid by using the handy-controller SFBHC (optional). Refer to instruction manual enclosed with this product for details. 19 SF4B-C Refer to the instruction manual for details. The instruction manual can be download from our website. PRECAUTIONS FOR PROPER USE Auxiliary output (Non-safety output) <Muting auxiliary output wiring> Auxiliary output setting Negative logic of OSSD (Factory setting) Normal mode Control outputs Emission (OSSD 1, OSSD 2) status Lockout halt Beam received Beam interrupted ON OFF ON ON **To trigger a large multi-purpose indicator during muting operation, connect the wiring as follows: As for lead wires other than below, perform wiring depending on your application. Emitter **This light curtain incorporates the auxiliary output (yellowgreen / black) for the non-safety output. The auxiliary output is incorporated with the emitter. Receiver Gray cable Do not use the auxiliary output for the purpose of stopping the device with SF4B-C installed. Failure to do so could result in serious injury or death. Muting Function (For SF4B-CA-J05 only) **Incorrect use of the muting control may cause accidents. Please understand the muting control fully, and use it. As for the muting control, the following international standards define the requirements. ISO 13849-1 (EN ISO 13849-1 / JIS B 9705-1) IEC 61496-1 (ANSI / UL 61496 / JIS B 9704-1) IEC 60204-1 (JIS B 9960-1) EN 415-4 ANSI B11.19-1990 ANSI/RIA R15.06-1999 **Use the muting control while the machine cycle is not in danger mode. Maintain safety with the other measure while the muting control is activated. **For the application that the muting control is activated when a workpiece passes through the sensor, place the muting sensor so that the conditions for the muting control cannot be satisfied by intrusion of personnel when the workpiece is passing through the sensor or the workpiece is not passing through it. **Be sure to check the operation of the muting function before its use. **This function turns the safety function of this light curtain into disabled temporarily. When the control outputs (OSSD 1, OSSD 2) are ON, this function is available for passing the workpiece through the sensing area of the light curtain without stopping the machinery. The muting function becomes valid when all the conditions listed below are satisfied. (1) The control outputs (OSSD 1, OSSD 2) shall be ON. (2) The output of the muting sensors A and B shall be changed from OFF (open) to ON. At this time, the time difference occurred by changing the output of the muting sensors A and B into ON status shall be within 0.03 to 3 sec. **The following devices, photoelectric sensor with semiconductor output, inductive proximity sensor, position switch on N.O. (Normally open) contact, etc. are available for applying to the muting sensor. Notes: 1) 0 to 3 sec. is allowable by using the handy controller Ver. 2.1 (SFB-HC) (optional) and connecting NO (Normally Open) type muting sensor to the input A, as well as connecting NC (Normally Closed) type muting sensor to the input B. 2) The muting indicator diagnosis function can be set with the handy controller Ver. 2 or later (SFB-HC) (optional), but it must be set to invalid. If the muting indicator diagnosis function is set to valid, the muting function cannot be used. 20 (Gray / Black) Large multi-purpose indicator input (Emitter side) (Red) Muting auxiliary output (Brown) +V + (Blue) 0 V - 24 V DC 10 % (Orange) Synchronization+ (Orange / Black) SynchronizationGray cable (with black line) (Orange / Black) Synchronization(Orange) Synchronization+ (Brown) +V (Blue) 0 V (Gray / Black) Large multi-purpose indicator input (Receiver side) Override function (For SF4B-CA-J05 only) **This function sets the safety function of this light curtain enabled forcibly. When using the muting function, the override function can be used to start the machinery at times such as when the control outputs (OSSD 1 and OSSD 2) are OFF or when the muting sensors are ON when the line is to be started. The override function becomes valid when all the conditions listed below are satisfied. (1) The signal shall be input to either muting sensor A, B, or A and B. (2) The override input (yellow) shall be short-circuited to 0 V or +V, and the emission halt input / reset input (pink) shall be opened. (3 sec. continuously) If one of the two conditions above becomes invalid or timing exceeds 60 sec. (Note 1), the override function becomes invalid. **The override function only operates when the interlock function is disabled (automatic reset). Notes: 1) By using handy-controller (SFB-HC) (optional) Ver.2.1 or later, a change between 60 and 600 sec. by 10 sec. per unit is possible. 2) The muting indicator diagnosis function can be set with the handy controller Ver. 2 or later (SFB-HC) (optional), but it must be set to invalid. If the muting indicator diagnosis function is set to valid, the muting function cannot be used. 3) The override function only operates when the interlock function is disabled (automatic reset). **Make sure manually to operate system for starting override function. Furthermore, the system shall be placed in area where all over the dangerous zone shall be comprehend and out side of the dangerous zone. **Using override function, make sure that there exist no operator in the dangerous zone, which may result in death or serious injury. SF4B-C Refer to the instruction manual for details. The instruction manual can be download from our website. PRECAUTIONS FOR PROPER USE Others Influence of reflective surfaces ** Do not use during the initial transient time (2 sec.) after the power supply is switched on. ** Avoid dust, dirt and steam. ** Take care that the light curtain does not come in direct contact with water, oil, grease, or organic solvents, such as, thinner, etc. ** Take care that the light curtain is not directly exposed to fluorescent light from a rapid-starter lamp or a high frequency lighting device, as it may affect the sensing performance. ** When this device is used in the "PSDI mode", an appropriate control circuit must be configured between this device and the machinery. For details, be sure to refer to the standards or regulations applicable in each region or country. ** To use this product in the U.S.A., refer to OSHA 1910. 212 and OSHA 1910. 217 for installation, and in Europe, refer to EN 999 as well. Observe your national and local requirements before installing this product. Install the light curtain by considering the effect of nearby reflective surfaces, and take countermeasures such as painting, masking, or changing the material of the reflective surface, etc. Failure to do so may cause the light curtain not to detect, resulting in serious body injury or death. **Install this device at a distance of at least A (m) (given below) away from reflective surfaces such as metal walls, floors, ceilings, workpiece, covers, panels or glass surfaces. Side view Emitter ** This catalog is a guide to select a suitable product. Be sure to read instruction manual attached to the product prior to its use. ** Both emitter and receiver are combined adjusted on factory setting, please apply both emitter and receiver with the same serial No. The serial No. is indicated on the plates of both emitter and receiver. (Indicated under model No.) ** Make sure to carry out the test run before regular operation. ** Do not use this product with machinery that cannot be stopped immediately during the operating cycle by means of an emergency stop system. Sensing area ** Make sure to install this product such that any part of the human body must pass through its sensing area in order to reach the dangerous parts of the machinery. Furthermore, ensure that some part of the operator's body always remains in the sensing area when operation is done with the dangerous parts of the machine. If the human body is not detected, there is a danger of serious injury or death. ** Do not use any reflection type or recursive reflection type arrangement. ** Multiple receivers (emitters) cannot be connected to one emitter (receiver). Example of correct installation Dangerous part Sensing area Protective structure Dangerous part Sensing area Example of Incorrect Installation Dangerous part Sensing area Dangerous part Top view Reflective ceiling A Reflective surface Receiver Emitter A Receiver Sensing range L Sensing range L A Reflective floor Distance between emitter and receiver (Setting distance L) 0.5 1.640 Allowable installation distance A 0.3 to 3 m 0.16 m 0.525 ft 0.984 to 9.843 ft L/2 x tan2 = 3 to 7 m L/2 x 0.105 (m) 9.843 to 22.966 ft 0.004 (in) ( = 3) Allowable installation distance A (m ft) 0.4 1.312 0.3 0.984 0.2 0.656 0.1 0.328 0 Install in this area Do not install in this area 1 3 5 7 3.281 9.843 16.404 22.966 Sensing range L (m ft) 9 29.528 Note: The effective aperture angle for this device is 2.5 or less (when L > 3m 9.843 ft) as required by IEC 61496-2, ANSI/UL 61496-2. However, install this device away from reflective surfaces considering an effective aperture angle of 3 to take care of beam misalignment, etc. during installation. Handy-controller This device enables to set each function using the handy-controller SFB-HC (optional). Among the functions, the contents related to the safety distance such as the size of the minimum sensing object and response time are varied depending on the setting condition. When setting each function, re-calculate the safety distance, and make enough space larger than the calculated safety distance. Failure to do so might cause the accident that the device cannot stop quickly before reaching the dangerous area of the machinery, resulting in the serious injury or death. **Refer to the instruction manual enclosed with the handycontroller for details of the function settings for using handy-controller SFB-HC (optional). Sensing area 21 SF4B-C PRECAUTIONS FOR PROPER USE Safety distance **Calculate the safety distance correctly, and always maintain a distance which is equal to or greater than the safety distance, between the sensing area of this light curtain and the dangerous parts of the machinery. (Please check the latest standards for the equation.) If the safety distance is miscalculated or if sufficient distance is not maintained, there is a danger of serious injury or death. **Before designing the system, refer to the relevant standards of the region where this device is to be used and then install this device. Emitter Dangerous part of machine S Beam axis Receiver S: Safety distance The sizes of the minimum sensing objects for this device vary depending on whether or not the floating blanking function is being used. Calculate the safety distance with the proper size of the minimum sensing object and appropriate equation. Size of minimum sensing object when applying floating blanking function Invalid SF4B-HC (A-J05) o25 mm (Min. sensing object o0.984 in o25 mm o0.984 in) SF4B-HC (A-J05) o45 mm (Min. sensing object o1.772 in o45 mm o1.772 in) Setting (Note) 1 beam 2 beam 3 beam channel channels channels o45 mm o65 mm o85 mm o1.772 in o2.559 in o3.346 in o85 mm o125 mm o165 mm o3.346 in o4.921 in o6.496 in Note: Refer to P. 5 for details of the floating blanking function. **Safety distance is calculated based on the following equation when a person moves perpendicular (normal intrusion) to the sensing area of the light curtain. In case the intrusion direction is not perpendicular to the sensing area, be sure to refer to the relevant standard (regional standard, specification of the machine, etc.) for details of the calculation. For use in Europe (EU) (as EN 999) (Also applicable to ISO 13855 / JIS B 9715) For intrusion direction perpendicular to the sensing area <In the case that the minimum sensing object is o40 mm o1.575 in or less> **Equation (1) S=KxT+C S: Safety distance (mm) Minimum required distance between the sensing area surface and the dangerous parts of the machine K: Intrusion velocity of operator's body or object (mm/sec.) Taken as 2,000 (mm/sec.) for calculation T: Response time of total equipment (sec.) T = Tm + TSF4B Tm: Maximum halting time of machinery (sec.) TSFC: Response time of the SF4B-C series (sec.) C: Additional distance calculated from the size of the minimum sensing object of the SF4B-C series (mm) However, the value of C cannot be under 0. C = 8 x (d - 14) d: Minimum sensing object diameter (mm) 22 Refer to the instruction manual for details. The instruction manual can be download from our website. **For calculating the safety distance "S", there are the following five cases. First calculate by substituting the value K = 2,000 (mm/sec.) in the equation above. Then, classify the obtained value of "S" into three cases, 1) S < 100, 2) 100 S 500, and 3) S > 500. For Case 3) S > 500, recalculate by substituting the value K = 1,600 (mm/ sec.). After that, classify the calculation result into two cases, 4) S 500 and 5) S > 500. For details, refer to the instruction manual enclosed with this product. **When this device is used in the "PSDI mode", an appropriate safety distance "S" must be calculated. For details, be sure to refer to the standards or regulations applicable in each region or country. <In the case that the minimum sensing object is o40 mm o1.575 in or more> **Equation (1) S=KxT+C S: Safety distance (mm) K: Intrusion velocity of operator's body or object (mm/sec.) Taken as 1,600 (mm/sec.) for calculation T: Response time of total equipment (sec.) T = Tm + TSF4B Tm: Maximum halting time of machinery (sec.) TSFC: Response time of the SF4B-C series (sec.) C: Additional distance calculated from the size of the minimum sensing object of the SF4B-C series (mm) C = 850 (mm) (Constant) For use in the United States of America (as per ANSI/RIA 15.06) **Equation (2) S = K x (TS + TC + TSF4B + Tbm) + Dpf S: Safety distance (mm) Minimum required distance between the sensing area surface and the dangerous parts of the machine K: Intrusion velocity {Recommended value in OSHA is 63 (inch/s) [ 1,600 (mm/sec.)] } ANSI/RIA 15.06 does not define the intrusion speed "K". When determining K, consider possible factors including physical ability of operators. TS: Halting time calculated from the operation time of the control element (air valve, etc.) (sec.) TC: Maximum response time of the control circuit required for functioning the brake (sec.) TSF4B: Response time of the SF4B-C series (sec.) Tbm: Additional halting time tolerance for the brake monitor (sec.) The following equation holds when the machine is equipped with a brake monitor. Tbm = Ta - (TS + TC) Ta: Setting time of brake monitor (sec.) When the machine is not equipped with a brake monitor, it is recommended that 20 % or more of (TS + TC) is taken as additional halting time. Dpf: Additional distance calculated from the size of the minimum sensing object of the device (mm) SF4B-HC (A-J05): Dpf = 61.2 mm 2.409 in SF4B-AC (A-J05): Dpf = 129.2 mm 5.087 in Dpf = 3.4 x (d - 0.276) (inch) 3.4 x (d - 7) (mm) d: Minimum sensing object diameter 0.985 (inch) 25 (mm) [SF4B-HC (A-J05)] Minimum sensing object diameter 1.772 (inch) 45 (mm) [SF4B-AC (A-J05)] **When the floating blanking function is applied, the minimum sensing object becomes large. According to ANSI/RIA 15.06, Dpf = 900 mm (3 ft) when d > 64 mm (2.5 inches). SF4B-C DIMENSIONS (Unit: mm in) SF4B-CA-J05 SF4B-C The CAD data in the dimensions can be downloaded from our website. MS-SF4BC-1 Light curtain 27.4 1.079 Assembly dimensions 2 0.079 19.6 0.772 MS-SF4BC-1 The figure depicts rear mounting using the standard mounting bracket MS-SF4BC-5 with the standard mounting bracket MS-SF4BC-5 (optional). 20 0.787 MS-SF4BC-1 B 20 0.787 B 6 x M3 mounting hole for countersunk screw 5 0.197 27.4 1.079 MS-SF4BC-5 F 2 0.079 2 0.079 2 0.079 F 2 0.079 10.7 0.421 E 2 0.079 10.7 0.421 (46.6 1.835) 120 A 4.724 C G 29.9 1.177 (46.6 1.835) 5.4 0.213 (2 0.079) 5.4 0.213 10 0.394 11.8 0.465 20 0. 120 A 27.4 C 4.724 1.079 2 0.079 19.6 0.772 33 1.299 D H 120 pitch A CBeam 4.724 o5 o0.197 Gray cable H Beam pitch o5 o0.197 Gray cable 5.4 0.213 10 0.394 11.8 0.465 21.6 0.850 5 0.19 2 0.079 108 4.252 3.2 0.126 20 0.787 21.6 0.850 H G 29.9 1.177 supporting bracket for use Protective height 108 4.252 (3.2 0.126) 120 A 4.724 C D 108 4.252 19.6 0.772 33 1.299 5.4 0.213 (2D0.079) E 5 0.197 2 0.079 Protective height 33 1.299 (3.2 0.126) 6 x M3 mounting hole for countersunk screw (optional) and the 19.6 intermediate 0.772 27.4 1.079 33 H 1.299 D G 2 0.079 108 4.252 (46.6 1.835) 2 0.079 G 5.4 0.213 11.8 0.465 10 0.394 21.6 0.850 Emitter 10.7 2 0.421 0.079 E 5.4 0.213 29.9 1.177 E 5.4 0.213 B 5.4 0.213 11.8 0.465 10 0.394 F 3.2 29.9 21.6 0.850 0.126 1.177 o5 o0.197 Gray cable (with black line) o5 o0.197 Gray cable (with black line) 5 2 0.0790.197 (46.6 1.835) 10.7 2 0.421 0.079 Receiver <Connector of the pigtailed type (with muting function) SF4B-CA-J05> (45 1.772) o15.6 o0.614 Model No. (45 1.772) SF4B-H12C (A-J05) o15.6 o0.614 SF4B-H16C (A-J05) SF4B-A8C (A-J05) SF4B-H20C (A-J05) SF4B-H24C (A-J05) SF4B-A12C (A-J05) SF4B-H28C (A-J05) SF4B-H32C (A-J05) SF4B-A16C (A-J05) SF4B-H36C (A-J05) SF4B-H40C (A-J05) SF4B-A20C (A-J05) SF4B-H48C (A-J05) SF4B-A24C (A-J05) SF4B-H56C (A-J05) SF4B-A28C (A-J05) SF4B-H64C (A-J05) SF4B-A32C (A-J05) SF4B-H72C (A-J05) SF4B-A36C (A-J05) SF4B-H80C (A-J05) SF4B-A40C (A-J05) Model No. G H SF4B-HC (A-J05) 21.7 0.854 20 0.787 SF4B-AC (A-J05) 41.7 1.642 40 1.575 A B C 294.4 11.591 374.4 14.740 454.4 17.890 534.4 21.039 614.4 24.189 694.4 27.339 774.4 30.488 854.4 33.638 1,014.4 39.937 1,174.4 46.236 1,334.4 52.535 1,494.4 58.835 1,654.4 65.134 279 10.984 359 14.134 439 17.283 519 20.433 599 23.583 679 26.732 759 29.882 839 33.031 999 39.331 1,159 45.630 1,319 51.929 1,479 58.228 1,639 64.528 263.4 10.370 343.4 13.520 423.4 16.669 503.4 19.819 583.4 22.969 663.4 26.118 743.4 29.268 823.4 32.417 983.4 38.717 1,143.4 45.016 1,303.4 51.315 1,463.4 57.614 1,623.4 63.913 D SF4B-HC (A-J05) 220 8.661 300 11.811 380 14.961 460 18.110 540 21.260 620 24.409 700 27.559 SF4B-AC (A-J05) -- 280 11.024 -- 440 17.323 -- 600 23.622 -- 780 30.709 760 29.921 940 37.008 920 36.220 1,100 43.307 1,080 42.520 1,260 49.606 1,240 48.819 1,420 55.906 1,400 55.118 1,580 62.205 1,580 62.205 E F -- -- -- -- -- -- -- -- -- -- -- -- -- -- 395 15.551 475 18.701 555 21.850 415 16.339 468 18.425 521 20.512 -- -- -- 854 33.622 961 37.835 1,068 42.047 23 SF4B-C DIMENSIONS (Unit: mm in) SF4B-CA-J05 SF4B-C (2 0.079) Assembly dimensions The CAD data in the dimensions can be downloaded from our website. MS-SF4BC-1 (2 0.079) Light curtain 27.4 1.079 The figure depicts side mounting using the standard mounting MS-SF4BC-5 with the standard mounting bracket MS-SF4BC-5 (optional). MS-SF4BC-1 (2 0.079) B 5 0.197 27.4 1.079 20 0.787 MS-SF4BC-5 25 K 0.984 6x M3 mounting hole 3 for countersunk screw 0.118 D J 5 0.197 (2 0.079) B 5 0.197 J 20 0.787 (46.6 1.835) 5.4 0.213 29.9 1.177 10 0.394 (2 0.079) C A 19.6 0.772 27.4 1.079 108 4.252 120 4.724 C A 5.4 0.213 bracket for use (2 0.079) (2 0.079) A C 120 27.4 4.724 1.079 108 4.252 H Beam pitch G A C 120 4.724 D 11.8 0.465 o5 o0.197 Gray cable Beam pitch H (46.6 1.835) 5 0.19 20 0.787 20 0.787 25 0.984 15 0.591 20 0.787 10 25 11.8 0.465 0.394 0.984 K 29.9 21.6 0.850 1.177 20 0.787 o5 o0.197 15 0.591 Gray cable 2 0.079 (with black line) 21.6 0.850 5 0.197 (3 0.118) (46.6 1.835) B 5 0.197 G 5.4 0.213 H 5 0.197 108 4.252 H D 2 0.079 (46.6 1.835) J (3 0.118) G 5.4 0.213 10 11.8 0.465 0.394 29.9 21.6 0.850 1.177 o5 o0.197 Gray cable (with black line) o5 o0.197 Gray cable 21.6 0.850 Emitter 10.7 0.421 Receiver <Connector of the pigtailed type (with muting function) SF4B-CA-J05> (45 1.772) o15.6 o0.614 Model No. (45 1.772) SF4B-H12C (A-J05) o15.6 o0.614 SF4B-H16C (A-J05) SF4B-A8C (A-J05) SF4B-H20C (A-J05) SF4B-H24C (A-J05) SF4B-A12C (A-J05) SF4B-H28C (A-J05) SF4B-H32C (A-J05) SF4B-A16C (A-J05) SF4B-H36C (A-J05) SF4B-H40C (A-J05) SF4B-A20C (A-J05) SF4B-H48C (A-J05) SF4B-A24C (A-J05) SF4B-H56C (A-J05) SF4B-A28C (A-J05) SF4B-H64C (A-J05) SF4B-A32C (A-J05) SF4B-H72C (A-J05) SF4B-A36C (A-J05) SF4B-H80C (A-J05) SF4B-A40C (A-J05) 24 Model No. G H SF4B-HC (A-J05) 21.7 0.854 20 0.787 SF4B-AC (A-J05) 41.7 1.642 40 1.575 (2 0. 27.4 1.079 15 0.591 Protective height 2 0.079 G 11.8 0.465 MS-SF4BC-1 (optional) and the intermediate 19.6 0.772 27.4 supporting 1.079 Protective height 120 4.724 D 19.6 5 0.197 0.772 27.4 1.079 20 0.787 10.7 0.421 10 0.394 2 0.079 29.9 1.177 15 0.591 3 0.118 10.7 0.421 6x M3 mounting hole for countersunk screw 108 4.252 20 0.787 25 K 0.984 19.6 0.772 27.4 bracket 1.079 A B C 294.4 11.591 374.4 14.740 454.4 17.890 534.4 21.039 614.4 24.189 694.4 27.339 774.4 30.488 854.4 33.638 1,014.4 39.937 1,174.4 46.236 1,334.4 52.535 1,494.4 58.835 1,654.4 65.134 279 10.984 359 14.134 439 17.283 519 20.433 599 23.583 679 26.732 759 29.882 839 33.031 999 39.331 1,159 45.630 1,319 51.929 1,479 58.228 1,639 64.528 263.4 10.370 343.4 13.520 423.4 16.669 503.4 19.819 583.4 22.969 663.4 26.118 743.4 29.268 823.4 32.417 983.4 38.717 1,143.4 45.016 1,303.4 51.315 1,463.4 57.614 1,623.4 63.913 D SF4B-HC (A-J05) 220 8.661 300 11.811 380 14.961 460 18.110 540 21.260 620 24.409 700 27.559 SF4B-AC (A-J05) -- 280 11.024 -- 440 17.323 -- 600 23.622 -- 780 30.709 760 29.921 940 37.008 920 36.220 1,100 43.307 1,080 42.520 1,260 49.606 1,240 48.819 1,420 55.906 1,400 55.118 1,580 62.205 1,580 62.205 J K -- -- -- -- -- -- -- -- -- -- -- -- -- -- 390 15.354 470 18.504 550 21.654 410 16.142 463 18.228 516 20.315 -- -- -- 849 33.425 956 37.638 1,063 41.850 J 10.7 SF4B-C DIMENSIONS (Unit: mm in) SF4B-CA-J05 The CAD data in the dimensions can be downloaded from our website. SF4B-C Light curtain Assembly dimensions The figure depicts rear mounting using the rear utility mounting bracket MS-SF4BC-2 (optional) and the intermediate supporting bracket for use with the utility mounting bracket MS-SF4BC-4 (optional). 19.6 0.772 (4.2 0.165) MS-SF4BC-2 19.6 0.772 B 10.6 0.417 MS-SF4BC-4 4 0.157 Protective height L D 120 M 4.724 108 4.252 P 32.2 1.268 D 19.6 0.772 10.8 0.425 5.4 0.213 5.4 0.213 M 120 4.724 (4.2 0.165) (4.2 0.165) 10.8 Protective 0.425 height 120 M 4.724 108 M 4.252 (4.2 0.165) 19.6 0.772 (4.2 0.165) 19.6 0.772 32.2 1.268 32.2 1.268 10.8 0.425 32.2 1.268 10.6 0.417 D LMS-SF4BC-4 4 0.157 19.6 0.772 19.6 0.772 10.8 5.4 0.213 0.425 5.4 0.213 B (4.2 0.165) (4.2 0.165) MS-SF4BC-2 (4.2 0.165) 120 4.724 D L L 108 4.252 10.6 0.417 108 4.252 B 10.6 0.417 4 0.157 P P 5.4 0.213 (46.6 1.835) 5.4 0.213 H Q 23.8 0.937 H Beam pitch H (46.6 1.835) Q (46.6 1.835) o5 o0.197 Gray cable o5 o0.197 Gray cable o5 o0.197 Gray cable (with black line) o5 o0.197 Gray cable (with black line) Emitter 5.4 0.213 N 5.4 0.213 Q 23.8 0.937 10 0.394 Q Beam pitch 10 0.394 8 0.315 8 0.315 H (46.6 1.835) N N 10 0.394 23 0.9 8 0.315 10 0.394 23.8 0.937 Receiver <Connector of the pigtailed type (with muting function) SF4B-CA-J05> (45 1.772) (45 1.772) o15.6 o0.614 o15.6 o0.614 Model No. B SF4B-H12C (A-J05) SF4B-H16C (A-J05) SF4B-A8C (A-J05) SF4B-H20C (A-J05) SF4B-H24C (A-J05) SF4B-A12C (A-J05) SF4B-H28C (A-J05) SF4B-H32C (A-J05) SF4B-A16C (A-J05) SF4B-H36C (A-J05) SF4B-H40C (A-J05) SF4B-A20C (A-J05) SF4B-H48C (A-J05) SF4B-A24C (A-J05) SF4B-H56C (A-J05) SF4B-A28C (A-J05) SF4B-H64C (A-J05) SF4B-A32C (A-J05) SF4B-H72C (A-J05) SF4B-A36C (A-J05) SF4B-H80C (A-J05) SF4B-A40C (A-J05) 279 10.984 359 14.134 439 17.283 519 20.433 599 23.583 679 26.732 759 29.882 839 33.031 999 39.331 1,159 45.630 1,319 51.929 1,479 58.228 1,639 64.528 Model No. H Q SF4B-HC (A-J05) 20 0.787 22.2 0.874 SF4B-AC (A-J05) 40 1.575 42.2 1.661 D SF4B-HC (A-J05) 220 8.661 300 11.811 380 14.961 460 18.110 540 21.260 620 24.409 700 27.559 SF4B-AC (A-J05) -- 280 11.024 -- 440 17.323 -- 600 23.622 -- 780 30.709 760 29.921 940 37.008 920 36.220 1,100 43.307 1,080 42.520 1,260 49.606 1,240 48.819 1,420 55.906 1,400 55.118 1,580 62.205 1,580 62.205 L M 316.4 12.457 396.4 15.606 476.4 18.756 556.4 21.906 636.4 25.055 716.4 28.205 796.4 31.354 876.4 34.504 1,036.4 40.803 1,196.4 47.102 1,356.4 53.402 1,516.4 59.701 1,676.4 66.000 264.4 10.409 344.4 13.559 424.4 16.709 504.4 19.858 584.4 23.008 664.4 26.157 744.4 29.307 824.4 32.457 984.4 38.756 1,144.4 45.055 1,304.4 51.354 1,464.4 57.654 1,624.4 63.953 N P -- -- -- -- -- -- -- -- -- -- -- -- -- -- 399.5 15.728 479.5 18.878 559.5 22.028 419.5 16.516 472.5 18.602 525.5 20.689 -- -- -- 858.5 33.799 965.5 38.012 1,072.5 42.224 25 SF4B-C DIMENSIONS (Unit: mm in) SF4B-CA-J05 The CAD data in the dimensions can be downloaded from our website. SF4B-C Light curtain Assembly dimensions The figure depicts space-saving mounting using the rear utility mounting bracket MS-SF4BC-2 (optional) and the intermediate supporting bracket for use with the utility mounting bracket MS-SF4BC-4 (optional). MS-SF4BC-2 19.6 0.772 MS-SF4BC-2 19.6 0.772 (4.2 0.165) 10.8 0.425 5.4 0.213 B 10.8 0.425 Protective height T 120 M 4.724 L D MS-SF4BC-4 5.4 0.213 10 0.394 8 0.315 23.8 0.937 H (46.6 1.835) 5.4 0.213 Q S 120 M 120 4.724M 4.724 Beam pitch (46.6 1.835) H H Q o5 o0.197 Gray cable 10 0.394 8 0.315 19.6 0.772 32.2 1.268 10.8 0.425 108 4.252 T S 4.2 0.165 4.2 (4.2 0.165) 0.165 D L M 108 4.252 120 4.724 Emitter (4.2 0.165) 5.4 0.213 4 0.157 B S 5.4 0.213 Q 10 0.394 8 0.315 o5 o0.197 Gray cable23.8 (with black line) 0.937 Receiver <Connector of the pigtailed type (with muting function) SF4B-CA-J05> (45 1.772) (45 1.772) o15.6 o0.614 o15.6 o0.614 Model No. B SF4B-H12C (A-J05) SF4B-H16C (A-J05) SF4B-A8C (A-J05) SF4B-H20C (A-J05) SF4B-H24C (A-J05) SF4B-A12C (A-J05) SF4B-H28C (A-J05) SF4B-H32C (A-J05) SF4B-A16C (A-J05) SF4B-H36C (A-J05) SF4B-H40C (A-J05) SF4B-A20C (A-J05) SF4B-H48C (A-J05) SF4B-A24C (A-J05) SF4B-H56C (A-J05) SF4B-A28C (A-J05) SF4B-H64C (A-J05) SF4B-A32C (A-J05) SF4B-H72C (A-J05) SF4B-A36C (A-J05) SF4B-H80C (A-J05) SF4B-A40C (A-J05) 26 279 10.984 359 14.134 439 17.283 519 20.433 599 23.583 679 26.732 759 29.882 839 33.031 999 39.331 1,159 45.630 1,319 51.929 1,479 58.228 1,639 64.528 Model No. H Q SF4B-HC (A-J05) 20 0.787 22.2 0.874 SF4B-AC (A-J05) 40 1.575 42.2 1.661 D SF4B-HC (A-J05) 220 8.661 300 11.811 380 14.961 460 18.110 540 21.260 620 24.409 700 27.559 SF4B-AC (A-J05) -- 280 11.024 -- 440 17.323 -- 600 23.622 -- 780 30.709 760 29.921 940 37.008 920 36.220 1,100 43.307 1,080 42.520 1,260 49.606 1,240 48.819 1,420 55.906 1,400 55.118 1,580 62.205 1,580 62.205 10.6 0.417 T 5.4 0.213 (46.6 1.835) H o5 o0.197 Gray cable o5 o0.197 Gray cable (with black line) 23.8 0.937 D L 10.6 0.417 108 4.252 (46.6 1.835) Beam pitch Q 19.6 0.772 10.8 0.425 5.4 0.213 Protective height L D 10.6 0.417108 4.252 4 0.157 19.6 0.772 19.6 0.772 32.2 1.268 32.2 1.268 4.2 0.165 5.4 0.213 MS-SF4BC-4 B 10.6 0.417 4 0.157 19.6 0.772 32.2 1.268 4.2 0.165 (4.2 0.165) L M 316.4 12.457 396.4 15.606 476.4 18.756 556.4 21.906 636.4 25.055 716.4 28.205 796.4 31.354 876.4 34.504 1,036.4 40.803 1,196.4 47.102 1,356.4 53.402 1,516.4 59.701 1,676.4 66.000 264.4 10.409 344.4 13.559 424.4 16.709 504.4 19.858 584.4 23.008 664.4 26.157 744.4 29.307 824.4 32.457 984.4 38.756 1,144.4 45.055 1,304.4 51.354 1,464.4 57.654 1,624.4 63.953 S T -- -- -- -- -- -- -- -- -- -- -- -- -- -- 382.9 15.075 462.9 18.224 542.9 21.374 402.9 15.862 455.9 17.949 508.9 20.035 -- -- -- 841.9 33.146 948.9 37.358 1,055.9 41.571 10 0.394 23.8 0.937 SF4B-C DIMENSIONS (Unit: mm in) SF4B-CA-J05 The CAD data in the dimensions can be downloaded from our website. SF4B-C Light curtain Assembly dimensions The figure depicts side mounting using the side utility mounting bracket MS-SF4BC-3 (optional) and the intermediate supporting bracket for use with the utility mounting bracket MS-SF4BC-4 (optional). MS-SF4BC-3 MS-SF4BC-3 (1.3 0.051) (1.3 0.051) MS-SF4BC-4 5 0.197 5.4 0.213 27.4 1.079 5.4 0.213 108 4.252 P 12.9 0.508 N 12.9 0.508 Q (46.6 1.835) 10 0.394 10 0.394 8.7 0.343 27.4 1.079 H 5.4 0.213 12.9 0.508 L M 120 4.724 L M 120 4.724 D H 27.4 1.079 H (46.6 1.835) Q o5 o0.197 Gray cable 108 4.252 5.4 5 0.213 0.197 Beam pitch H 2.3 0.091 2.3 0.091 108 4.252 12.9 0.508 Beam12.9 pitch 0.508 Q (46.6 1.835) 8.7 0.343 o5 o0.197 Gray cable 28.7 1.13 28.7 1.13 120 4.724 M L 31.5 1.24 12.9 0.508 31.5 1.24 Protective height D 120 4.724 M L 108 4.252 5.4 0.213 D P N 5 0.197 B 34.3 1.35 34.3 1.35 Protective height MS-SF4BC-4 B 19.6 0.772 34.3 1.35 2.3 0.091 34.3 1.35 2.3 0.091 19.6 0.772 31.5 1.24 19.6 0.772 31.5 1.24 12.9 0.508 (1.3 0.051) 19.6 0.772 12.9 0.508 o5 o0.197 Gray cable (with black line) D B 5.4 5 0.213 0.197 P 27.4 1.079 (46.6 1.835) N 5.4 0.213 Q o5 o0.197 Gray cable (with black line) 8.7 0.343 10 0.394 5.4 0.213 8.7 0.343 28.7 1.13 Emitter 1 28.7 1.13 Receiver <Connector of the pigtailed type (with muting function) SF4B-CA-J05> (45 1.772) (45 1.772) o15.6 o0.614 o15.6 o0.614 Model No. B SF4B-H12C (A-J05) SF4B-H16C (A-J05) SF4B-A8C (A-J05) SF4B-H20C (A-J05) SF4B-H24C (A-J05) SF4B-A12C (A-J05) SF4B-H28C (A-J05) SF4B-H32C (A-J05) SF4B-A16C (A-J05) SF4B-H36C (A-J05) SF4B-H40C (A-J05) SF4B-A20C (A-J05) SF4B-H48C (A-J05) SF4B-A24C (A-J05) SF4B-H56C (A-J05) SF4B-A28C (A-J05) SF4B-H64C (A-J05) SF4B-A32C (A-J05) SF4B-H72C (A-J05) SF4B-A36C (A-J05) SF4B-H80C (A-J05) SF4B-A40C (A-J05) 279 10.984 359 14.134 439 17.283 519 20.433 599 23.583 679 26.732 759 29.882 839 33.031 999 39.331 1,159 45.630 1,319 51.929 1,479 58.228 1,639 64.528 Model No. H Q SF4B-HC (A-J05) 20 0.787 22.2 0.874 SF4B-AC (A-J05) 40 1.575 42.2 1.661 D SF4B-HC (A-J05) 220 8.661 300 11.811 380 14.961 460 18.110 540 21.260 620 24.409 700 27.559 SF4B-AC (A-J05) -- 280 11.024 -- 440 17.323 -- 600 23.622 -- 780 30.709 760 29.921 940 37.008 920 36.220 1,100 43.307 1,080 42.520 1,260 49.606 1,240 48.819 1,420 55.906 1,400 55.118 1,580 62.205 1,580 62.205 L M 316.4 12.457 396.4 15.606 476.4 18.756 556.4 21.906 636.4 25.055 716.4 28.205 796.4 31.354 876.4 34.504 1,036.4 40.803 1,196.4 47.102 1,356.4 53.402 1,516.4 59.701 1,676.4 66.000 264.4 10.409 344.4 13.559 424.4 16.709 504.4 19.858 584.4 23.008 664.4 26.157 744.4 29.307 824.4 32.457 984.4 38.756 1,144.4 45.055 1,304.4 51.354 1,464.4 57.654 1,624.4 63.953 N P -- -- -- -- -- -- -- -- -- -- -- -- -- -- 399.5 15.728 479.5 18.878 559.5 22.028 419.5 16.516 472.5 18.602 525.5 20.689 -- -- -- 858.5 33.799 965.5 38.012 1,072.5 42.224 27 SF4B-C DIMENSIONS (Unit: mm in) SF4B-CA-J05 The CAD data in the dimensions can be downloaded from our website. SF4B-C Light curtain Assembly dimensions The figure depicts space-saving mounting side utility mounting bracket MS-SF4BC-3 (optional) and the intermediate supporting bracket for use with the utility mounting bracket MS-SF4BC-4 (optional). MS-SF4BC-3 (1.3 0.051) (1.3 0.051) 27.4 1.079 19.6 0.772 B 5.4 0.213 T 5 0.197 5.4 0.213 S S 10 0.394 28.7 1.13 120 M L D 4.724 8.7 0.343 10 0.394 L M 120 M L 4.724 12.9 0.508 H Beam pitch 12.9 H 0.508 (46.6 1.835) Q 120 4.724 H Beam pitch L M 120 4.724 108 4.252 (46.6 1.835) H o5 o0.197 Gray cable (with black line) o5 o0.197 Gray cable o5 o0.197 Gray cable 8.7 0.343 28.7 1.13 Protective height 108 4.252 5.4 0.213 12.9 0.508 12.9 5 0.197 0.508 5.4 0.213 Q (46.6 1.835) T 12.9 0.508 Protective height MS-SF4BC-4 31.5 1.240 108 2.3 0.091 4.252 27.4 19.6 0.772 1.079 34.3 1.350 31.5 1.24012.9 0.508 2.3 0.091 34.3 1.350 34.3 1.350 D 31.5 1.240 2.3 0.091 12.9 0.508 19.6 0.772 19.6 0.772 34.3 27.4 1.079 1.350 MS-SF4BC-4 B 12.9 0.508 MS-SF4BC-3 Emitter D D 5.4 108 0.213 5 4.252 0.197 Q (1.3 0.051) (1.3 0.051) 27.4 1.079 31.5 1.240 2.3 0.091 B B 5.4T 0.213 5 0.197 T S 5.4 0.213 (46.6 1.835) S 5.4 0.213 Q 10 0.394 8.7 0.343 o5 o0.197 Gray cable 28.7 8.7 0.343 (with black line) 1.13 Receiver 10 0.394 28.7 1.13 <Connector of the pigtailed type (with muting function) SF4B-CA-J05> (45 1.772) (45 1.772) o15.6 o0.614 o15.6 o0.614 Model No. B SF4B-H12C (A-J05) SF4B-H16C (A-J05) SF4B-A8C (A-J05) SF4B-H20C (A-J05) SF4B-H24C (A-J05) SF4B-A12C (A-J05) SF4B-H28C (A-J05) SF4B-H32C (A-J05) SF4B-A16C (A-J05) SF4B-H36C (A-J05) SF4B-H40C (A-J05) SF4B-A20C (A-J05) SF4B-H48C (A-J05) SF4B-A24C (A-J05) SF4B-H56C (A-J05) SF4B-A28C (A-J05) SF4B-H64C (A-J05) SF4B-A32C (A-J05) SF4B-H72C (A-J05) SF4B-A36C (A-J05) SF4B-H80C (A-J05) SF4B-A40C (A-J05) 28 279 10.984 359 14.134 439 17.283 519 20.433 599 23.583 679 26.732 759 29.882 839 33.031 999 39.331 1,159 45.630 1,319 51.929 1,479 58.228 1,639 64.528 Model No. H Q SF4B-HC (A-J05) 20 0.787 22.2 0.874 SF4B-AC (A-J05) 40 1.575 42.2 1.661 D SF4B-HC (A-J05) 220 8.661 300 11.811 380 14.961 460 18.110 540 21.260 620 24.409 700 27.559 SF4B-AC (A-J05) -- 280 11.024 -- 440 17.323 -- 600 23.622 -- 780 30.709 760 29.921 940 37.008 920 36.220 1,100 43.307 1,080 42.520 1,260 49.606 1,240 48.819 1,420 55.906 1,400 55.118 1,580 62.205 1,580 62.205 L M 316.4 12.457 396.4 15.606 476.4 18.756 556.4 21.906 636.4 25.055 716.4 28.205 796.4 31.354 876.4 34.504 1,036.4 40.803 1,196.4 47.102 1,356.4 53.402 1,516.4 59.701 1,676.4 66.000 264.4 10.409 344.4 13.559 424.4 16.709 504.4 19.858 584.4 23.008 664.4 26.157 744.4 29.307 824.4 32.457 984.4 38.756 1,144.4 45.055 1,304.4 51.354 1,464.4 57.654 1,624.4 63.953 S T -- -- -- -- -- -- -- -- -- -- -- -- -- -- 382.9 15.075 462.9 18.224 542.9 21.374 402.9 15.862 455.9 17.949 508.9 20.035 -- -- -- 841.9 33.146 948.9 37.358 1,055.9 41.571 SF4B-C DIMENSIONS (Unit: mm in) The CAD data in the dimensions can be downloaded from our website. MS-SF4BC-1 Standard mounting bracket (optional) t1.5 t 0.059 t 1.5 t 0.059 9.3 0.366 5.4 17 0.669 0.213 2 0.079 10.8 0.425 2 0.079 2 x M3 mounting hole (for main body mounting) 45 45 9.3 0.366 5.4 17 0.669 0.213 9.3 0.366 5.4 0.213 9.3 0.366 5.4 0.213 45 R7.2 R0.283 10.7 0.421 5 0.197 11.8 0.465 21.6 0.850 Material: Stainless steel Four bracket set (two each R and L type) Eight M3 (length: 5 mm 0.197 in) hexagon-sockethead bolts and four 5M flat washers are attached. Rear utility mounting bracket (optional) t 2 t 0.079 t 2 t 0.079 3 0.118 9.3 0.366 15 0.591 5.4 0.213 (6 0.236) 4 0.157 8 0.315 12 0.472 R7.2 R0.283 104 19.6 0.772 28 1.102 2 x M3 mounting hole (for main body mounting) 28 1.102 10 0.394 104 20.4 0.803 36.4 1.433 22.7 0.894 17 0.669 2 x M3 mounting hole (for main body mounting) 11 0.433 (4 0.157) 5.5 0.217 14 0.551 23.8 0.937 Material: Stainless steel Four bracket set (two each R and L type) Eight M3 (length: 5 mm 0.197 in) hexagon-sockethead bolts and four 5M flat washers are attached. Side utility mounting bracket (optional) t 2 t 0.079 t 2 t 0.079 28 1.102 28 1.102 32.5 1.280 32.5 1.280 2 x M3 mounting hole (for main body mounting) 104 5.4 0.213 8.7 0.343 13.7 0.539 19.4 28.7 0.764 1.130 10 0.394 22.7 0.894 8 0.315 R7.2 R0.283 MS-SF4BC-3 15 0.591 4 0.157 (6 0.236) 10 0.394 4 0.157 14 0.551 23.8 0.937 10 0.394 12 0.472 11 0.433 5.5 0.217 8 0.315 3 0.118 9.3 15 0.366 0.591 5.4 0.213 19.6 0.772 20.4 36.4 0.803 1.433 22.7 0.894 17 0.669 R7.2 R0.283 2 x M3 mounting hole (for main body mounting) 29.4 1.157 15.7 0.618 11.5 10.7 0.421 0.453 6.5 0.256 MS-SF4BC-2 8 0.315 10 0.394 5 0.197 11.8 0.465 21.6 0.850 10 0.394 45 R7.2 R0.283 29.4 10 0.394 1.157 15.7 11.5 0.618 6.5 0.453 0.256 10.8 0.425 9.3 0.366 9.3 0.366 2 x M3 mounting hole (for main body mounting) 104 5.4 0.213 8.7 0.343 10 0.394 R7.2 R0.283 13.7 0.539 19.4 0.764 28.7 1.130 Material: Stainless steel Four bracket set (two each R and L type) Eight M3 (length: 5 mm 0.197 in) hexagon-sockethead bolts and four 5M flat washers are attached. 15 0.591 22.7 0.894 29 SF4B-C DIMENSIONS (Unit: mm in) The CAD data in the dimensions can be downloaded from our website. MS-SF4BC-4 Intermediate supporting bracket for use with utility mounting bracket (optional) <For rear mounting> <For side mounting> 30.6 1.205 20.6 0.811 6 0.236 30 1.181 0.5 0.020 20 0.787 5.4 0.213 33.5 1.319 26 1.024 18.5 0.728 5.4 0.213 38.5 1.516 26 1.024 18.5 0.728 13.5 0.531 11 0.433 13.5 0.531 11 0.433 4 0.157 10.5 0.413 20.5 0.807 27.5 1.083 1 0.039 t 1.5 t 0.059 32.2 1.268 20.6 0.811 (20.2 0.795) 3.6 0.142 9 0.354 31.5 1.240 15.5 0.610 15.5 0.610 (28.5 1.122) t 1.5 t 0.059 28.5 1.122 38.7 1.524 (20.2 0.795) 34.3 1.350 22.7 0.894 11.1 5.7 0.437 0.224 34.7 1.366 11.2 0.441 5.2 0.205 t 2 t 0.079 15 0.591 7.2 0.283 t 2 t 0.079 Material: Stainless steel 2 Two pcs. M5 flat washers, two pcs. assembled M3 (length: 6 mm 0.236 in) hexagon-socket-head bolts for rear mounting, two pcs. attachments for side mounting Note: The numbers of sets required by SF4B-HC (A-J05) (40 or more beam axes) and SF4B-AC (A-J05) (20 or more beam axes) are as follows: SF4B-H40C (A-J05), SF4B-H48C (A-J05), SF4B-H56C (A-J05), SF4B-A20C (A-J05), SF4B-A24C (A-J05), SF4B-A28C (A-J05): 1set SF4B-H64C (A-J05), SF4B-H72C (A-J05), SF4B-H80C (A-J05), SF4B-A32C (A-J05), SF4B-A36C (A-J05), SF4B-A40C (A-J05): 2 sets MS-SF4BC-5 Intermediate supporting bracket for use with the standard mounting bracket (optional) <For rear mounting> <For side mounting> t 2 t 0.079 t 2 t 0.079 24.6 0.969 33 1.299 30.4 1.197 22.4 0.882 22.8 0.898 14.8 0.583 9.8 0.386 18.7 0.736 13.7 0.539 13.4 0.528 8.7 0.343 2 x M3 mounting hole for countersunk screw 6 x M3 mounting hole for countersunk screw 30 20 1.181 0.787 5 0.197 40 1.575 20 0.787 20 60 0.787 2.362 25 0.984 15 0.591 Material: Stainless steel 2 Two pcs. for rear mounting, two pcs. for side mounting Note: The numbers of sets required by SF4B-HC (A-J05) (40 or more beam axes) andSF4B-AC (A-J05) (20 or more beam axes) are as follows: SF4B-H40C (A-J05), SF4B-H48C (A-J05), SF4B-H56C (A-J05), SF4B-A20C (A-J05), SF4B-A24C (A-J05), SF4B-A28C (A-J05): 1 set SF4B-H64C (A-J05), SF4B-H72C (A-J05), SF4B-H80C (A-J05), SF4B-A32C (A-J05), SF4B-A36C (A-J05), SF4B-A40C (A-J05): 2 sets 30 SF4B-C DIMENSIONS (Unit: mm in) SFB-CC-MU The CAD data in the dimensions can be downloaded from our website. Mating cable with connector on one end (optional) 45 1.772 SFB-CCJ-MU 45 1.772 L Mating cable with connectors on both ends (optional) 45 1.772 L o15.6 o0.614 o15.6 o0.614 o15.6 o0.614 o6 o0.236 o6 o0.236 ** Length: L ** Length: L Model No. Length: L Model No. Length: L SFB-CC3-MU 3,000 118.110 SFB-CCJ3D-MU SFB-CC7-MU 7,000 275.591 SFB-CCJ3E-MU SFB-CC10-MU 10,000 393.701 SFB-CCJ10D-MU SFB-CCJ10E-MU SF-C13 Control unit (optional) 6.75 0.266 4 0.157 34.5 1.358 35 1.378 67.3 2.650 130 5.118 10 0.394 13.5 0.531 SF-IND-2 5 0.197 SFB-HC Handy-controller (optional) 65 2.559 30 1.181 6 0.236 25.4 1.000 23 0.906 3 x 5=15 0.118 x 0.197=0.591 10,000 393.701 o6 o0.236 cables, 0.5 m 1.640 ft long 91.6 3.606 6.5 0.256 80 3.150 13 0.512 80.8 3.181 Suitable for 35 mm 1.378 in width DIN rail 3,000 118.110 5 0.197 140 5.512 22.5 0.886 Large display unit for light curtain (optional) 22.8 0.898 18.3 0.720 25 35.5 0.984 1.398 40.1 23 1.579 0.906 4.6 0.181 18 0.709 28 1.102 5.5 0.217 o3.6 o0.142 cables, 3 m 9.843 ft long 25.4 1.000 t 1.6 t 0.063 6.6 0.260 10.4 0.409 Material: Bracket *** Cold rolled carbon steel (SPCC)(Black chromate) Enclosure *** POM Cover *** Polycarbonate 31 Please contact .......... 2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan Global Sales Department Telephone: +81-568-33-7861 Facsimile: +81-568-33-8591 panasonic.net/id/pidsx/global All Rights Reserved (c) No. CE-SF4BC-7 June, 2013 Specifications are subject to change without notice. 2013 Printed in Japan